phase4,mod12.chimney

phase4,mod12.chimney

Professional Development

14 Qs

quiz-placeholder

Similar activities

Phase 3 Revision

Phase 3 Revision

Professional Development

15 Qs

Pengenalan Draught Survey [DMM]

Pengenalan Draught Survey [DMM]

Professional Development

15 Qs

Phase4mod1 Legislation

Phase4mod1 Legislation

Professional Development

10 Qs

Ship Dimensions

Ship Dimensions

Professional Development

15 Qs

8710 unit 6 ppt 4

8710 unit 6 ppt 4

Professional Development

13 Qs

The Nervous System

The Nervous System

Professional Development

18 Qs

Transistores

Transistores

Professional Development

10 Qs

Science Quiz-Electricity and Circuits

Science Quiz-Electricity and Circuits

KG - Professional Development

10 Qs

phase4,mod12.chimney

phase4,mod12.chimney

Assessment

Quiz

Science

Professional Development

Hard

Created by

Craig Boothright

Used 8+ times

FREE Resource

14 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A Gas appliance with a natural draught open flue incorporating a draught diverter and natural draught burner would be catergorised as which type of appliance?

b11.

b14.

b21.

c11.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following open flues do not necessarily need a terminal fitted when a gas fire is to be installed?

A chimney with 225mm salt glaze lining.

A chimney with a 125mm Flexible flue liner.

A pre-cast Flue with 125mm twin wall flue termination.

A flue box with 150mm twin wall flue pipe.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When shall the fitting of a bird guard to a chimney be considered?

Where trees are close to the flue terminal.

Where no terminal is fitted.

Where the flue terminal is below two meters.

where there is known to be a problem of birds nesting

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If a restrictor is found in the throat of a brick chimney when a gas fire is fitted:

It must be removed.

it must be permanently fixed in the open position.

The Fire must only be below 7kw.

A gas fire is not allowed with this type of flue.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A natural draught balanced flue of a 20kw boiler must terminate at least how far from the bottom of a openable window?

300mm.

600mm.

1200mm.

1500mm.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When double wall flue pipes are run externally ist is important, in order to prevent condensation, to ensure the fue lenght does not exceed:

12m.

20m.

28m.

33m.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The minimum cross sectional area of a new flue block system for a gas fire must be:

12000mm2 with no dimension less than 75mm.

12000mm2 with no dimension less than 90mm.

16500mm2 with no dimension less than 75mm.

16500mm2 with no dimension less than 90mm.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?