phase4mod7setting

phase4mod7setting

Professional Development

9 Qs

quiz-placeholder

Similar activities

Forces and Energy

Forces and Energy

3rd Grade - Professional Development

7 Qs

phase4,mod12.chimney

phase4,mod12.chimney

Professional Development

14 Qs

ilmu pengetahuan alam

ilmu pengetahuan alam

University - Professional Development

10 Qs

Final  weather + climate study guide

Final weather + climate study guide

KG - Professional Development

12 Qs

Acronyms

Acronyms

Professional Development

11 Qs

Heat Terms Mult. choice

Heat Terms Mult. choice

Professional Development

14 Qs

Air can be compressed

Air can be compressed

1st Grade - Professional Development

8 Qs

Meteorology

Meteorology

KG - Professional Development

11 Qs

phase4mod7setting

phase4mod7setting

Assessment

Quiz

Science

Professional Development

Hard

Created by

Craig Boothright

Used 4+ times

FREE Resource

9 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The breather hole of a meter regulator is provided:

To allow the diaphragm to move up and down.

To compensate for changes in atmospheric pressure.

To allow a vent should 'lock up' occur.

To allow a vent for when inlet pressure is too high.

2.

FILL IN THE BLANK QUESTION

1 min • 1 pt

Standing pressure is that pressure measured when:

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A gas escape from the breather hole of a regulator indicates:

Faulty spring.

Bent spindle.

Split diaphragm.

Worn valve seating.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To increase the outlet pressure of a meter regulator you must:

Increase the pressure on the spring.

Decrease the pressure on the spring

Meter regulator is factory set.

Acquire specialist tools from the manufacturer.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The working pressure at a meter regulator must be measured:

With all appliances turned off.

With appliances in operation.

Prior to a tightness test.

With only pilot lights in operation.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is medium pressure gas?

Above 2bar.

Below 75mbar.

The same as low pressure.

Above 75mb but below 2 Bar.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Governor 'Lock up' will occur:

When all appliance and pilots are turned off.

When there is a gas escape on the supply.

When the inlet pressure to the regulator is greater than 50mb.

When the supply to the regulator has been turned off.

8.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Domestic medium to low pressure meter installations need to be located outside of the property in what?

A surface mounted meter box.

A built in (flush mounted) meter box.

A purpose built housing.

All of the above.

9.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The working pressure of a domestic meter regulator should be set at:

20mb +/_2mb

21mb +/_2mb

25mb +/_2mb

Is dependent upon the number of appliances fitted.

Discover more resources for Science