Copper Tube and Fittings Exam

Copper Tube and Fittings Exam

University

20 Qs

quiz-placeholder

Similar activities

REVISION 1 : TOPIC 7,8&9[AR,INVENTORIES & NCA]

REVISION 1 : TOPIC 7,8&9[AR,INVENTORIES & NCA]

1st Grade - University

20 Qs

Body Language Exposed

Body Language Exposed

KG - University

15 Qs

P-Economic Quiz

P-Economic Quiz

University

20 Qs

REVISION 3 : TOPIC 3, 4, 5 & 7

REVISION 3 : TOPIC 3, 4, 5 & 7

1st Grade - University

20 Qs

Student Centric

Student Centric

University

20 Qs

Quiz Aviasi p 3

Quiz Aviasi p 3

KG - Professional Development

16 Qs

Spongebob #ICTUSD 060

Spongebob #ICTUSD 060

University

20 Qs

EDUC 213 - FINALS QUIZ 2

EDUC 213 - FINALS QUIZ 2

University

15 Qs

Copper Tube and Fittings Exam

Copper Tube and Fittings Exam

Assessment

Quiz

Professional Development

University

Medium

Created by

jake wellander

Used 7+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The process of joining tubes and fittings by heating the materials and melting a filler metal into the joint to seal the tubes together is called

soldering

brazing

rolling

grooving

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A 1-inch nominal type L copper tube has an outside diameter of

7/8"

1"

1-1/8"

1-1/4"

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A 3/4-inch copper tube has an outside diameter of 3/4 inch. The tube is most likely type

K

M

ACR

DWV

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The information printed on the outside of copper tubing does not include the

tube type

joining method

manufacturer name

country of origin

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The part of the hanger that touches or connects directly to the tube is called the

connector

structural attachment

vibration isolator

tube attachment

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To insert a channel,

twist it into position along the slotted side

slide it into position on the flat side

bend it into position along the slotted side

slide it sideways until it touches the adjacent channel

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To reduce turbulence, the space between the fittings of a 2-inch diameter tube should be at least

10"

20"

30"

40"

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?