4-6 Morgan KC

4-6 Morgan KC

Professional Development

10 Qs

quiz-placeholder

Similar activities

Pengetahun Filsafat

Pengetahun Filsafat

Professional Development

10 Qs

exercises unit 2

exercises unit 2

Professional Development

11 Qs

Quiz 2

Quiz 2

Professional Development

10 Qs

Debate Calidad VOC 2023

Debate Calidad VOC 2023

Professional Development

15 Qs

Pokémon Master Challenge

Pokémon Master Challenge

Professional Development

15 Qs

GENERAL KNOWLEDGE QUIZ - 1

GENERAL KNOWLEDGE QUIZ - 1

Professional Development

11 Qs

Windows OS Security

Windows OS Security

Professional Development

11 Qs

COBAA COBAA

COBAA COBAA

Professional Development

8 Qs

4-6 Morgan KC

4-6 Morgan KC

Assessment

Quiz

Others

Professional Development

Practice Problem

Medium

Created by

dr. Mahenta

Used 3+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the most prevalent cause of equipment-related adverse outcomes according to closed claims?

Device malfunction

Misuse of anesthesia gas delivery systems

Improper calibration

Lack of oxygen supply

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of the mechanical ventilator in the anesthesia machine?

To control the flow of medical gases

To deliver gases to the patient's airway

To vaporize anesthetics

To reduce the pressure of gases

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What safety feature of anesthesia machines helps ensure a minimum oxygen concentration of 25%?

Double-circuit system design

Pressure sensors for oxygen monitoring

Automatic shutdown in case of oxygen failure

Linkage of nitrous oxide gas flow to oxygen gas flow

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the advantage of a piston ventilator in anesthesia machines?

Enhanced temperature control

Improved oxygen concentration

Reduced risk of gas leaks

Ability to deliver accurate tidal volumes

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be avoided when using the oxygen flush valve during the inspiratory cycle of a ventilator?

Closing the ventilator spill valve

Decreasing the circuit pressure

Increasing the fresh gas flow

Opening the APL valve

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is a common cause of large discrepancies between set and actual tidal volume during volume-controlled ventilation?

Breathing circuit compliance

Patient's lung compliance

Gas compression

Ventilator peak airway pressure limit

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of waste-gas scavengers in anesthesia equipment?

To dispose of excess anesthetic gases

To monitor patient CO levels

To regulate oxygen flow

To prevent circuit leaks

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?