Ph 3 - Electrical checkpoint test

Ph 3 - Electrical checkpoint test

Professional Development

40 Qs

quiz-placeholder

Similar activities

Cannock Inspection and Testing

Cannock Inspection and Testing

Professional Development

35 Qs

BASIC ELECTRIC

BASIC ELECTRIC

Professional Development

40 Qs

Electrical technology

Electrical technology

Professional Development

37 Qs

Cannock Fault finding DEC23

Cannock Fault finding DEC23

Professional Development

36 Qs

EC-I

EC-I

Professional Development

40 Qs

Ham Radio Technician Exam - T3

Ham Radio Technician Exam - T3

9th Grade - Professional Development

35 Qs

Generator and Transformer

Generator and Transformer

Professional Development

40 Qs

ELECTRICAL MACHINES-II QUIZ IIEEE-A and B

ELECTRICAL MACHINES-II QUIZ IIEEE-A and B

Professional Development

40 Qs

Ph 3 - Electrical checkpoint test

Ph 3 - Electrical checkpoint test

Assessment

Quiz

Other

Professional Development

Medium

Created by

Ben Ashford

Used 23+ times

FREE Resource

40 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which part of the Building Regulations covers electrical installation?

Part J

Part L

Part G

Part P

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is not classed as minor works?

The connection of an immersion heater with new flex cable from an existing fused spur

The installation of a replacement heating circulator

The replacement of a consumer unit

Fault-finding on a central heating control system

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The 18th Edition IET Wiring Regulations is also known as which British Standard document?

BS 7671

BS 6351

BS 5476

BS 6644

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What fault is shown in this image?

Incorrect continuity

Incorrect polarity

Reversed phases

Reversed neutral

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

At what stage should a proving unit be used?

After confirming that the supply is dead

Before confirming that the supply is dead

Before and after confirming that the supply is dead

Before and after confirming that the current is correct

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What minimum size should the earth cable be between a TN-S supply and the MET connection?

6mm²

10mm²

12mm²

16mm²

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What device is being checked in the image below?

Thermistor

Capacitor

Thermocouple

Relay