Gas Pipework Installation Quiz no4

Gas Pipework Installation Quiz no4

1st Grade

27 Qs

quiz-placeholder

Similar activities

SEÑALES 2

SEÑALES 2

KG - 8th Grade

22 Qs

EVALUACIÓN AUXILIAR DE FARMACIA 4

EVALUACIÓN AUXILIAR DE FARMACIA 4

KG - 5th Grade

28 Qs

Rysunek Techniczny

Rysunek Techniczny

KG - University

23 Qs

AU.32 organizacja transportu styczeń 2020

AU.32 organizacja transportu styczeń 2020

1st Grade

30 Qs

Chapter 2 Book A Revision

Chapter 2 Book A Revision

1st Grade

25 Qs

Building Laws Quiz 5 & 6- BP220 & PD 957

Building Laws Quiz 5 & 6- BP220 & PD 957

KG - Professional Development

25 Qs

UTS XI TAB EUAB

UTS XI TAB EUAB

1st - 12th Grade

30 Qs

ALAT UKUR MEKANIK

ALAT UKUR MEKANIK

1st - 3rd Grade

30 Qs

Gas Pipework Installation Quiz no4

Gas Pipework Installation Quiz no4

Assessment

Quiz

Professional Development

1st Grade

Hard

Created by

Graham Rogerson

Used 2+ times

FREE Resource

27 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The maximum interval between horizontal pipework supports for 15 mm copper gas pipework installed between solid timber joists is:

1.0 m.

1.5 m.

2.5 m.

3.5 m.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The minimum size solid timber joist that can be notched for a gas pipe is:

50 mm.

75 mm.

100 mm.

150 mm.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where gas pipework is buried in a floor screed, what is the minimum cover above the pipe?

5 mm.

10 mm.

25 mm.

100 mm.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Gas pipework installed behind dry lining shall:

Be made of steel only.

Need no additional protection.

Be suitably wrapped in tape only.

Be suitably encased by building material.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Gas pipework installed within walls of timber frame and light steel-framed construction shall:

Be made of steel only.

Have only welded joints.

Be left unsupported to allow for movement.

Be run within purpose-designed channels or ducts.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Above ground external gas pipework shall be protected against:

Painting

The weather

The risk of mechanical damage

The risk of unauthorised alterations

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Polyethylene (PE) gas pipework in private gardens, with no vehicular traffic, shall have a MINIMUM depth of cover of:

375 mm with marker tape between 75 mm above the pipework

450 mm with marker tape between 75 mm above the pipework

375 mm with marker tape between 100 mm and 300 mm above the pipework

450 mm with marker tape between 100 mm and 300 mm above the pipework