8202L3SANPPT1

8202L3SANPPT1

12th Grade

52 Qs

quiz-placeholder

Similar activities

Law Chapter 15: Employment Law (Test Review)

Law Chapter 15: Employment Law (Test Review)

9th - 12th Grade

50 Qs

Mountains and Geologic Structures

Mountains and Geologic Structures

11th - 12th Grade

47 Qs

1 MT Medical Terminology Review (mid Spring)

1 MT Medical Terminology Review (mid Spring)

9th - 12th Grade

53 Qs

Quiz on Gas Laws and Water Boiling Point

Quiz on Gas Laws and Water Boiling Point

12th Grade

49 Qs

Urinary System

Urinary System

10th - 12th Grade

50 Qs

Vet Applications- Suffixes

Vet Applications- Suffixes

10th - 12th Grade

48 Qs

Chapter 8 Female Reproductive System Simmons

Chapter 8 Female Reproductive System Simmons

9th - 12th Grade

52 Qs

Urinary system quiz :0

Urinary system quiz :0

10th - 12th Grade

50 Qs

8202L3SANPPT1

8202L3SANPPT1

Assessment

Quiz

Other

12th Grade

Hard

Created by

William Heron

FREE Resource

52 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is NOT a type of sanitation system listed in the UK?

Primary ventilated stack system

Secondary ventilated stack system

Tertiary ventilated stack system

Stub stack

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum gradient that must be kept for the branches in a primary ventilated stack system according to BS EN 12056?

2.5° per metre

5° per metre

10° per metre

15° per metre

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a primary ventilated stack system, how should all sanitary appliances be arranged in relation to the discharge stack?

Separately from the discharge stack

Directly above the discharge stack

Closely grouped to the discharge stack

At a minimum distance of 50 cm from the discharge stack

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to the design of a primary ventilated stack system, are separate ventilation pipes required?

Yes, they are always required

No, but only if guidelines in BS EN 12056 are followed

Yes, but only for appliances far from the stack

No, they are never required

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to BS EN 12056, how should all sanitary appliances be arranged in relation to the discharge stack?

They should be randomly connected.

They must be closely grouped to the discharge stack.

They should be connected with flexible hoses.

They must be placed at least 5 meters away from the discharge stack.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended gradient for discharge pipe branches to ensure proper flow?

10° per metre

2° per metre

5° per metre

15° per metre

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of bends should be avoided in the vertical discharge stack to prevent compression?

90° bends

Knuckle bends

45° bends

Long radius bends

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?