Electrical Safety Regulations Quiz

Electrical Safety Regulations Quiz

12th Grade

19 Qs

quiz-placeholder

Similar activities

Ulangkaji MTA3012

Ulangkaji MTA3012

12th Grade

21 Qs

Exploring Textile Fibres

Exploring Textile Fibres

12th Grade

15 Qs

KAWALAN MOTOR

KAWALAN MOTOR

9th - 12th Grade

15 Qs

nutrient 3

nutrient 3

9th - 12th Grade

23 Qs

08.01.03 Orthographic Projection

08.01.03 Orthographic Projection

9th - 12th Grade

20 Qs

Simple Future Tense (be going to)

Simple Future Tense (be going to)

9th - 12th Grade

15 Qs

PTS Tema 5 atau Tematik 3e

PTS Tema 5 atau Tematik 3e

1st Grade - Professional Development

20 Qs

Kuiz Matematik Tahun 2

Kuiz Matematik Tahun 2

2nd Grade - University

15 Qs

Electrical Safety Regulations Quiz

Electrical Safety Regulations Quiz

Assessment

Quiz

Education

12th Grade

Hard

Created by

Chris Barlow

FREE Resource

19 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should the source of the FELV system be according to Regulation 411.7.4?

A transformer with at least complex separation between windings

A transformer with at least simple separation between windings

A semiconductor device that is part of a FELV system

A direct connection to the primary circuit without any protection

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to Regulation 411.8.1.2, what is the maximum nominal voltage of the reduced low voltage circuits?

110 V AC rms between lines

63.5 V to earthed neutral, single-phase

55 V to earthed midpoint, single-phase

55 V AC rms between lines

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum value of earth fault loop impedance (Zs) for nominal voltages of 55 V and 63.5 V with a disconnection time of 5 s as per Regulation 411.8.3?

Specified in Table 41.6

Calculated by the formula in Regulation 411.4.4

Listed in the overcurrent device table

Not specified and must be calculated for each installation

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What must every plug, socket-outlet, luminaire supporting coupler (LSC), device for connecting a luminaire (DCL), and cable coupler in a FELV system have according to Regulation 411.7.5?

A protective conductor contact

A dimensionally compatible use with other system types in the same premises

A semiconductor device

A direct connection to the primary circuit

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to Table 4.16, what is the maximum earth fault loop impedance (Zs) in ohms for a single-phase circuit with a 63 A rating and a nominal voltage of 55 V for Type B circuit-breakers?

0.75 ohms

0.60 ohms

0.65 ohms

0.52 ohms

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the correct value of the maximum earth fault loop impedance (Zs) for a three-phase circuit with a 10 A rating and a nominal voltage of 63.5 V for Type C and D circuit-breakers as per Table 4.16?

0.60 ohms

0.52 ohms

1.21 ohms

0.60 ohms

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

As per the notes in the image, what is the value of the factor Cmin used to determine the circuit loop impedances in Table 4.16?

0.80

0.95

1.00

0.90

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?