315E Quiz Part 1-3 paper 2  (revised)

315E Quiz Part 1-3 paper 2 (revised)

1st Grade

12 Qs

quiz-placeholder

Similar activities

POST TEST "REVOLUSI INDUSTRI"

POST TEST "REVOLUSI INDUSTRI"

1st Grade

10 Qs

Latihan Daya Tahan

Latihan Daya Tahan

1st - 5th Grade

15 Qs

Electronics Components Quiz

Electronics Components Quiz

1st Grade

10 Qs

Quiz1

Quiz1

1st Grade

10 Qs

Quiz BINSAI 12

Quiz BINSAI 12

1st Grade

10 Qs

Body mass index (BMI) ​

Body mass index (BMI) ​

KG - Professional Development

10 Qs

Innovation & Invention

Innovation & Invention

1st Grade

10 Qs

Introduction to Computer COM111 CA 1

Introduction to Computer COM111 CA 1

1st Grade

10 Qs

315E Quiz Part 1-3 paper 2  (revised)

315E Quiz Part 1-3 paper 2 (revised)

Assessment

Quiz

Education

1st Grade

Hard

Created by

James Jones

Used 3+ times

FREE Resource

12 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In certain cases, the requirements of BS 7671 need to be supplemented by the requirements or recommendations of other British Standards for certain aspects or parts of the installation. Which of the following is not an example of this:

Explosive atmospheres

Telecommunications systems

Electric fences

Life safety and firefighting applications

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When is it permissible to make an intended departure from a requirement of BS 7671?

At the request of the client

Where it is not cost-effective to comply fully with relevant requirements

Where temporary work is carried out

Where the resultant degree of safety is not less than would be obtained by compliance

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Who is responsible for the design of an electrical installation?

A skilled person

An instructed person

An ordinary person

A responsible person

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following does not necessarily have to be taken into consideration when determining the cross-sectional area of conductors?

Energy Efficiency

Maximum admissible conductor temperature

Method of installation

Voltage drop

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The phrase 'An overcurrent occurring in a circuit which is electrically sound' defines which of the following?

A short-circuit current

An earth-fault current

A prospective fault current

An overload current

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The definition 'Conductive part of equipment which can be touched and which is not normally live, but which can become live under fault conditions' describes which of the following?

Extraneous-conductive-part

Exposed-conductive-part

Live part

Protective conductor

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When considering types of system earthing, what is the meaning of the first letter 'T' in the designation 'TT'?

All live parts of the installation are isolated from Earth

There is a direct connection of one point of the system to Earth

There is a direct electrical connection between exposed-conductive-parts of the installation and Earth that is independent from the earthing of any point of the power system

The protective function is provided by a conductor seperate from the neutral conductor