PEC Sizes (0mm-76mm)

PEC Sizes (0mm-76mm)

University

42 Qs

quiz-placeholder

Similar activities

Wave Properties Quiz

Wave Properties Quiz

10th Grade - University

40 Qs

Hematology Platings- Prelims

Hematology Platings- Prelims

University

45 Qs

Chapter 60 Principles

Chapter 60 Principles

University

37 Qs

 SAS IPA 7 SMP DT

SAS IPA 7 SMP DT

7th Grade - University

40 Qs

DRILL Element Symbols 41-60

DRILL Element Symbols 41-60

9th Grade - University

40 Qs

Genetics Vocabulary Practice

Genetics Vocabulary Practice

7th Grade - University

47 Qs

Safety Rules and Lab/Safety Equipment

Safety Rules and Lab/Safety Equipment

7th Grade - University

39 Qs

ULANGAN IPA BAB 1

ULANGAN IPA BAB 1

12th Grade - University

40 Qs

PEC Sizes (0mm-76mm)

PEC Sizes (0mm-76mm)

Assessment

Quiz

Science

University

Hard

Created by

Reggie Tano

FREE Resource

42 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Metal covers for boxes shall be lined with firmly attached insulating material NOT less than

0.80 mm.

0.50 mm.

0.90 mm.

0.70 mm.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The construction of metal cabinets and cutout boxes shall be such as to secure strength and rigidity. If constructed of uncoated sheet steel, the metal thickness should NOT be less than

1.5 mm

1.8 mm

1.35 mm

2 mm

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Cabinet and cutout boxes shall have an air space of at least ______ between the base of the device and the wall of any metal cabinet or cutout box in which the device is mounted.

1 mm

2 mm

3 mm

4 mm

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a damp or wet locations, cabinets and cutout boxes of the surface type shall be mounted with at least _____ air space between the enclosure and the wall.

4 mm

6 mm

6.4 mm

5 mm

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In walls or ceilings of concrete, tile, or other non-combustible materials, boxes and fittings shall be installed that the front edge of the box or fitting will NOT set back of the finished surface more than

7 mm

4 mm.

5 mm

6.4 mm.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Nails where used as a fastening means, shall be permitted to pass through the interior of the enclosure if located within ____ of the back or ends of the enclosure.

5 mm

6.4 mm

4.3 mm

5.2 mm

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where flexible tubing is used to encase the conductors, the tubing shall extend from the last insulating support to NOT less than.

6.4 mm

4.3 mm

8.1 mm

5.2 mm

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?