units 3-5

units 3-5

Professional Development

20 Qs

quiz-placeholder

Similar activities

WCS 1101-4 - Knowledge Assessment

WCS 1101-4 - Knowledge Assessment

Professional Development

20 Qs

2018 IFGC CH 4B

2018 IFGC CH 4B

Professional Development

25 Qs

KSS AIR

KSS AIR

Professional Development

20 Qs

2018 IPC CH 7B Study Quiz

2018 IPC CH 7B Study Quiz

Professional Development

25 Qs

Compressor

Compressor

Professional Development

21 Qs

AIR CONDITIONER SYSTEM PRE/POST TETS

AIR CONDITIONER SYSTEM PRE/POST TETS

Professional Development

20 Qs

Int. Hydraulics Mod 4

Int. Hydraulics Mod 4

Professional Development

15 Qs

Medical Gas Systems 2021 1-25

Medical Gas Systems 2021 1-25

Professional Development

25 Qs

units 3-5

units 3-5

Assessment

Quiz

Other

Professional Development

Hard

Created by

william kemp

Used 3+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Carbon monoxide shall activate a local alarm when the CO level exceeds ?

10 ppm

5 ppm

15 ppm

20 ppm

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When the dew point system temperature exceeds _________, the required alarms shall activate.

42 F

38 F

35 F

21 F

3.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Liquid ring compressors service water and seal water shall be treated to control ____________.

Chlorine

Waterborne pathogens

Hyper chlorination

Electrolosis

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medical air compressor systems shall have a ___________ means to prevent backflow through all off-cycle compressors.

Manual

Semi- automatic

Automatic

All the above

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medical air filters shall be located immediately upstream of the ___________.

After coolers

Final line regulator

Pressure indicator

Receiver

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medical air filters shall be sized for 100% of the system peak calculated demand and be rated for a minimum of _______ percent efficiency @ ________ micron or greater.

95% @ 0.5

98% @ 1

98% @ 0.1

100% @ 1

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medical air sources shall only be used for____________.

Instrument air

Air-operating devices

Human respiratory applications

All of the above

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?