UA Local 467 Section 6.2 Quizizz

UA Local 467 Section 6.2 Quizizz

Professional Development

21 Qs

quiz-placeholder

Similar activities

Security+ Cengage Module6: Mobile and Embedded Device Security

Security+ Cengage Module6: Mobile and Embedded Device Security

Professional Development

20 Qs

PT716A_Day3_18601917108_Pilot Plant Scale Upfor liquidorals

PT716A_Day3_18601917108_Pilot Plant Scale Upfor liquidorals

University - Professional Development

20 Qs

Inhouse Training BIM - PT Yodya Karya (Persero)

Inhouse Training BIM - PT Yodya Karya (Persero)

Professional Development

20 Qs

Culture générale

Culture générale

11th Grade - Professional Development

16 Qs

Security Plus 1-03

Security Plus 1-03

Professional Development

17 Qs

Lógica de programação e Java

Lógica de programação e Java

Professional Development

18 Qs

AUT 208 Week 1 Quiz

AUT 208 Week 1 Quiz

Professional Development

20 Qs

Google Professional Architect 4 - 61 to 80

Google Professional Architect 4 - 61 to 80

Professional Development

20 Qs

UA Local 467 Section 6.2 Quizizz

UA Local 467 Section 6.2 Quizizz

Assessment

Quiz

Instructional Technology

Professional Development

Medium

Created by

Louis Nunes

Used 23+ times

FREE Resource

21 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

____ is the desired value to be maintained by a system.

Control point

Setpoint

Offset

Working point

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A(n) ____ is the actual value that a control system experiences at any given time.

control point

setpoint

offset

controlled variable

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

____ is control in which a controller produces only a 0% or 100% output signal.

Closed loop control

Anticipator control

ON/OFF (digital) control

Overshooting control

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

HVAC electrical controls often use ____ VAC for proper operation of the control system.

6

24

115

230

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

______ is the decreasing of a controlled variable below the controller setpoint.

Undershooting

Overshooting

Offsetting

Undercutting

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A variable-speed drive permits volume control of the ____.

humidifier

return fan

heating coil

supply fan or pump

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In system pressure control, the ____ is connected to a controller which opens or closes a controlled device such as a damper or valve.

control point

humidity control

pressure sensor

differential pressure control