1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In buildings constructed in accordance with the provisions of conventional light-frame construction bearing partitions perpendicular to joists may not be offset from supporting girders, walls or partitions ___________________ unless such joists are of sufficient size to carry the additional load.

12 inches

24 inches

more than twice the joist depth

more than the joist depth

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A poured concrete basement wall is 7 feet high and 7.5 inches thick. The lateral backfill soil load is 60 psf. The unbalance backfill height is 7 feet. What is the required re-bar size and spacing?

#6 at 48"

#7 at 39"

#7 at 60"

Plain Concrete no re-bar required

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For the purpose of required natural lighting, any room is permitted to be considered as a portion of an adjoining room where _______ of the area of the common wall is open and unobstructed and provides an opening of not less than one-tenth of the floor area of the interior room or 25 square feet, whichever is greater. Exceptions ignored.

one-half

one-third

one-quarter

one-tenth

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A plain masonry basement wall is 7 feet high . The lateral backfill soil load is 60 psf. The unbalance backfill height is 7 feet. What is the minimum required wall thickness and the type of wall required.

8" Hollow

10 Hollow

10" Solid

8" Solid

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the allowable area of a Group F-2 single story building of Type IIIB Construction equipped throughout with an automatic sprinkler

18,000 square feet

18,000 square feet

36,000 square feet

72,000 square feet

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In buildings constructed in accordance with the provisions of conventional light-frame construction trimmer and header joists must be doubled, or of lumber of equivalent cross section, where the span of the header exceeds ______________.

4 feet

5 feet

6 feet

7 feet

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A wall designed to resist lateral forces parallel to the plane of a wall.

Braced wall

Cripple wall

Vertical wall

Shearwall

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?