71 - 105

71 - 105

12th Grade

35 Qs

quiz-placeholder

Similar activities

Lab Safety Review

Lab Safety Review

8th - 12th Grade

34 Qs

Câu hỏi trắc nghiệm về động học phân tử

Câu hỏi trắc nghiệm về động học phân tử

10th Grade - University

30 Qs

Đề thi thử THPT số 26

Đề thi thử THPT số 26

12th Grade

40 Qs

Motion

Motion

12th Grade

35 Qs

Flinn Lab Safety quiz

Flinn Lab Safety quiz

9th - 12th Grade

30 Qs

ĐỀ LÝ THUYẾT

ĐỀ LÝ THUYẾT

12th Grade

35 Qs

LT CHƯƠNG 1,2 VL 11

LT CHƯƠNG 1,2 VL 11

12th Grade

37 Qs

IED 3.1-3.3 Study Guide Quiz

IED 3.1-3.3 Study Guide Quiz

9th - 12th Grade

40 Qs

71 - 105

71 - 105

Assessment

Quiz

Physics

12th Grade

Easy

Created by

Fernando Lop

Used 2+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

35 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Flame barriers protecng openings in exterior walls in adjacent stories shall have a minimum fire-resistance rang of ________.

20 minutes

45 minutes

1 hour

2 hours

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A roof eave extending to within 5 feet of the line used to determine fire separaon distance may be constructed of all of the following materials except ________.

heavy-mber construcon

noncombusble construcon

fire-retardant-treated wood

½-hour fire-resistance-rated construcon

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Materials required to be noncombusble shall be tested in accordance with ________.

ASTM E119

ASTM E136

ASTM E84

ASTM C636

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A projecon extending beyond an exterior wall that is located 4 feet from an interior lot line shall be located such that a minimum of ________ inches is provided between the lot line and the edge of the projecon.

12

24

32

40

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Fire walls must be constructed of noncombusble materials unless separang buildings of Type ________ construcon.

I

III

IV

V

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A fire wall separang Type VA buildings housing Group M occupancies must have a minimum fire-resistance rang of ________ hour(s).

1

2

3

4

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a Type IIB building containing a Group B occupancy, what is the minimum required fire-resistance rang for a fire wall?

1 hour

2 hour

3 hour

4 hour

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?