pp1 central heating 1.4

pp1 central heating 1.4

Professional Development

10 Qs

quiz-placeholder

Similar activities

Furnace Wiring

Furnace Wiring

Professional Development

10 Qs

pp5 Heating System Components Quiz

pp5 Heating System Components Quiz

Professional Development

11 Qs

PP 12 Central Heating Decommissioning Quiz

PP 12 Central Heating Decommissioning Quiz

Professional Development

6 Qs

Central Heating Quiz phase 2 1.4/3

Central Heating Quiz phase 2 1.4/3

Professional Development

9 Qs

Sustainable Energy

Sustainable Energy

12th Grade - Professional Development

7 Qs

Control System

Control System

Professional Development

10 Qs

Central Heating Quiz phase 2 LO1.4/1

Central Heating Quiz phase 2 LO1.4/1

Professional Development

15 Qs

Central Heating Systems QuizL3P2U7,1.7

Central Heating Systems QuizL3P2U7,1.7

Professional Development

10 Qs

pp1 central heating 1.4

pp1 central heating 1.4

Assessment

Quiz

Science

Professional Development

Medium

Created by

jon May

Used 53+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which document gives advice on how to satisfy the requirements of L1a and L1b regarding the design efficiency of domestic CH systems?

BS EN 442

BS EN 12828

Manufacturers’ instructions

Domestic Heating Compliance Guide (DHCG)

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the main purpose of central heating?

To provide cooling in every room

To provide lighting in every room

To provide ventilation in every room

To provide thermal comfort within a property

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which type of heating uses an ‘indirect’ gas-fired heater to warm air circulated by a fan through ductwork under the floor?

Warm air heating

Electric storage heaters

Wet central heating

Air source heat pumps

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When the outside temperature is −1⁰C, what type of central heating allows all rooms in a property to be heated at the same time to a specific temperature set by the customer?

Full central heating

Background central heating

Pumped heating with gravity hot water

Selective central heating

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of system is installed mainly on a cost basis and uses a smaller boiler or heat emitters to only take the chill out of the rooms and heat the rooms to a lower temperature?

Sealed, pressurised systems

Pumped heating with gravity hot water

Background central heating

Fully pumped system

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What has central heating been replaced with over the past 10 years?

Open fire in each room

Gravity hot water system

heat pumps

Electric storage heaters

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What will the customer be mindful of when considering a central heating system?

Maintenance

Running costs

Efficiency

All of the above