EL0018 Topics 1, 2 & 3

EL0018 Topics 1, 2 & 3

University

30 Qs

quiz-placeholder

Similar activities

Rec-101 Electrical Mod 1 Quiz

Rec-101 Electrical Mod 1 Quiz

University

34 Qs

Rec-105 Midterm

Rec-105 Midterm

University

30 Qs

intro electricity 1.0

intro electricity 1.0

University

29 Qs

203 Electrical Installations Technology

203 Electrical Installations Technology

11th Grade - Professional Development

30 Qs

Unit 2 -Part 2

Unit 2 -Part 2

University

26 Qs

unit 501-S5

unit 501-S5

University

25 Qs

Circuital Dilemma

Circuital Dilemma

University

30 Qs

Instrument test #2

Instrument test #2

University

26 Qs

EL0018 Topics 1, 2 & 3

EL0018 Topics 1, 2 & 3

Assessment

Quiz

Other

University

Medium

Created by

Matt G

Used 38+ times

FREE Resource

30 questions

Show all answers

1.

FILL IN THE BLANK QUESTION

1 min • 1 pt

What is the furthest measurement for the vertical distance above a surface that is deemed within arms reach?

Answer explanation

AS 3000 1.4.16 Arms Reach

2.

FILL IN THE BLANK QUESTION

1 min • 1 pt

What is the clause that defines the term indirect contact

3.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

What are the 4 methods of basic protection that protects from "direct contact"

Insulation

Barriers or Enclosures

Obstacles

Placing out of Reach

Circuit Protection

Answer explanation

AS 3000 1.5.4.2 Methods of Protection

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum allowable percentage voltage drop for any low voltage installation?

10%

6%

5%

2%

Answer explanation

3.6.2 Voltage Drop Value is 5%

5.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

What are the 4 acceptable methods to determine maximum demand?

Calculation

Limitation

Measurement

Assessment

Determination

Answer explanation

2.2.2 Maximum Demand

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Do paints, varnishes, enamels or similar products alone meet the requirements for 'protection by insulation'

Yes

No

Answer explanation

1.5.4.3 Protection by Insulation

Generally not considered as providing adequate insulation for basic protection.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum allowable temperature for a hand held non-metallic device?

65°C

70°C

40°C

55°C

Answer explanation

AS 3000 Table 4.1