t511/t711 ST Day5 Review Quiz

t511/t711 ST Day5 Review Quiz

Professional Development

10 Qs

quiz-placeholder

Similar activities

LIBGEN

LIBGEN

KG - Professional Development

12 Qs

space

space

Professional Development

11 Qs

t511/t711 ST Day 6 Review

t511/t711 ST Day 6 Review

Professional Development

10 Qs

chestionar

chestionar

Professional Development

10 Qs

Solar System Exploration

Solar System Exploration

Professional Development

10 Qs

Quiz Program budaya

Quiz Program budaya

Professional Development

10 Qs

Assessment & Evidence

Assessment & Evidence

Professional Development

10 Qs

t511/t711 ST Day5 Review Quiz

t511/t711 ST Day5 Review Quiz

Assessment

Quiz

Education

Professional Development

Hard

Created by

John Lu

Used 2+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

What is the task of the transfer unit ?

Holding the probes.

Moving the probes over the whole range of reagent storage, analyzer unit, sampling unit.

Detect the cuvette (present or not present).

Providing level detection for all probes.

2.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

When is level detection used on the reagent probes?

For reagent level detection.

For initialization of the probes.

For RVC(Reagent Volume Check).

For teaching the modules / teach transfer unit

3.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

When is level detection used on the sample probes?

For RVC(Reagent Volume Check)

For level sensing of open tubes

For level sensing in closed tubes

For teaching the modules / teach transfer unit

4.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

On the t711 transfer units which probes have the heating function?

R1 probe

R2 probe

R3 probe

S1 probe

5.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

What statements are right about the probe with heating function?

One sensor is for temperature control.

One sensor is for temperature monitoring.

the target temperature for the probe is 37oC.

If the temprtature difference exceed  1oC  there will be an error.

6.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

What are the initialization steps of the transfer units?

Calibrate Tools

Probe bent check

Move range check

Probe referencing followed by rinsing of probes in washtubes.

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

On the t711 transfer units, which probe is used to reconstitute the lyophilized reagent?

R1 probe

R2 probe

R3 probe

S1 probe