GMJ 9189 Phase 3 Cold water MCQ part 1

GMJ 9189 Phase 3 Cold water MCQ part 1

Professional Development

10 Qs

quiz-placeholder

Similar activities

Introduction to AI - Healthcare & Business

Introduction to AI - Healthcare & Business

University - Professional Development

10 Qs

ADC-UNIT2

ADC-UNIT2

Professional Development

15 Qs

BM4085 - Business IT

BM4085 - Business IT

Professional Development

12 Qs

ECP Quiz on B+L UOD & Ultra monthly SVS

ECP Quiz on B+L UOD & Ultra monthly SVS

Professional Development

10 Qs

ISO 9001 Internal Auditing DEC 2024

ISO 9001 Internal Auditing DEC 2024

Professional Development

13 Qs

Facts on thermometer 🌡

Facts on thermometer 🌡

4th Grade - Professional Development

14 Qs

VERY HARD SPACE

VERY HARD SPACE

Professional Development

7 Qs

FaZe Rug

FaZe Rug

KG - Professional Development

10 Qs

GMJ 9189 Phase 3 Cold water MCQ part 1

GMJ 9189 Phase 3 Cold water MCQ part 1

Assessment

Quiz

Science

Professional Development

Medium

Created by

Glen Johnson

Used 8+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How can the cold water supply pressure to a property be identified?

By contacting the local council or using a pressure gauge at the supply to the FOV

By contacting the local council or using a weir gauge at the kitchen sink

By contacting the water undertaker or using a pressure gauge at the cistern-fed outlets

By contacting the water undertaker or using a pressure gauge at the kitchen sink

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which formula can be used to determine flow rates through a pipe?

Q = Av

Q = A÷v

Q = m/s

Q = V2

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What term is given to the length of pipe when all fittings and components are considered during pipe sizing?

Velocity length

Actual length

Mean length

Equivalent length

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is not a source of information that should be consulted to assist in pipe sizing for cold water systems?

BS EN 806 -2: 2012

BS EN 806-3: 2012

BS 8558: 2015

BS 4213: 2004

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to guidance, all pipes and joints of a cold water system should be designed for a service life of:

50 years at a temperature of 25C and a design pressure of 5 bar

50 years at a temperature of 20C and a design pressure of 10 bar

25 years at a temperature of 20C and a design pressure of 15 bar

25 years at a temperature of 25C and a design pressure of 10 bar

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended storage capacity of a CWSC supplying cold and hot water to a house?

100 litres minimum

150 litres minimum

230 litres minimum

350 litres minimum

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended flow velocity of cold water within pipework?

As close as practically possible to 2.5m/s

Between 0.5m/s and 2m/s

As close as practically possible to 3.5m/s

Between 0.25m/s and 1.5m/s

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?

Discover more resources for Science