1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

When fault at F,

CB open,

CT sense the current

CB open,

Trip circuit closed thus trip coil energized,

Relay coil energized and close,

CT sense the current

CT sense the current,

CB open

CT sense the current,

Relay coil energized and close,

Trip circuit closed thus trip coil energized,

CB open

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Each protection zone consist of primary and protection zone which are.....

Primary protection is main protection has delay action time.

Backup protection operate when primary protection fail to function

Primary protection is second line of defense

Backup protection ensure quick action than primary protection

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Miniature Circuit Breaker (MCB) and Molded Case Circuit Breaker operate in overload and short circuit condition by using......

Overload protection by solenoid

Short circuit protection by bi-metallic strip

Overload protection by using arc chute

Short circuit protection by bi-metallic strip

Overload protection by bi-metallic strip

Short circuit protection by arc chute

Overload protection by bi-metallic strip

Short circuit protection by solenoid

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

SF6 Circuit Breaker offer more advantages compared to oil circuit breaker, air circuit breaker and vacuum circuit breaker which are......

No risk of explosion

Expensive due to high cost of SF6 gas

Complicated safety regulation

Quite large size

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

The formula for new per unit

True

False

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Steps for fault current calculation are.......

  1. 1. New Vbase

  2. 2. New pu

  3. 3. Reactance diagram

  4. 4. Total pu value

  5. 5. Fault current

  1. 1. Single line diagram

  2. 2. New Vbase and New pu

  3. 3. Reactance diagram

  4. 4. Total pu value

  5. 5. Fault current

  1. 1. Single line diagram

  2. 2. New pu and total pu

  3. 3. Reactance diagram

  4. 4. Fault current

  1. 1. New Vbase and New pu

  2. 2. Reactance diagram

  3. 3. Total pu value

  4. 4. Fault current

  5. 5. Single line diagram

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Distance relay operate depending upon the impedance between point of fault and point the relay installed.

True

False

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?