What is the purpose of permanent decommissioning of a hot water system?

Hot Water Systems Decommissioning Quiz L3P2U6,2.1

Quiz
•
Other
•
Professional Development
•
Hard

Craig Boothright
FREE Resource
9 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
To completely remove the system
To temporarily shut down the system
To extend the system
To repair the system
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What should be done to avoid water stagnation during permanent decommissioning?
Drain the system to a suitable location
Remove all pipework and fittings
Cap off the internal stop tap
Turn off the cold water supply
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
When is temporary decommissioning of a hot water system conducted?
When the system is being permanently removed
When the system is being extended
When the system is being serviced or repaired
When the system is no longer required
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What should be done before the decommissioning process starts?
Apply warning notices and signs
Isolate the fuel/electricity supply
Notify the relevant person
Isolate the water supply
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What should be done if there are other trades on site that require water to work?
Ignore their water requirements
Ask them to use water from a different source
Continue with the decommissioning process as planned
Notify them in advance to make alternative water arrangements
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What should be done to isolate the hot water supply during temporary decommissioning?
Isolate the cold water supply
Isolate the electricity supply
Isolate the whole property
Isolate the section of pipework being worked on
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What should be done with the system water during temporary decommissioning?
Dispose of it in the top water drain
Dispose of it on the road
Dispose of it on the property pathway
Dispose of it down the foul water drain
8.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What should be done if there is no drain point for the system water?
Dispose of the water in the hot water storage cylinder
Dispose of the water in the cold water feed cistern
Dispose of the water in the lowest draw-off point
Install a drain point for future use
9.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What should be done with the pipework sections left drained for a period of time?
Leave them open for ventilation
Cap them off to prevent dirt and vermin/insects ingress
Remove them completely from the system
Replace them with new pipework sections
Similar Resources on Quizizz
10 questions
Info Sharing & Quiz (4/4) - Circular Economy & E-waste

Quiz
•
Professional Development
12 questions
Health & Safety

Quiz
•
Professional Development
10 questions
Supply_PKT-2_September'23

Quiz
•
Professional Development
10 questions
Health and safety

Quiz
•
Professional Development
10 questions
2122 Level 3 cutting

Quiz
•
Professional Development
12 questions
black holes

Quiz
•
KG - Professional Dev...
14 questions
First_Test_Ver_A

Quiz
•
Professional Development
10 questions
HAVAL H6 HEV 001-5

Quiz
•
Professional Development
Popular Resources on Quizizz
15 questions
Multiplication Facts

Quiz
•
4th Grade
25 questions
SS Combined Advisory Quiz

Quiz
•
6th - 8th Grade
40 questions
Week 4 Student In Class Practice Set

Quiz
•
9th - 12th Grade
40 questions
SOL: ILE DNA Tech, Gen, Evol 2025

Quiz
•
9th - 12th Grade
20 questions
NC Universities (R2H)

Quiz
•
9th - 12th Grade
15 questions
June Review Quiz

Quiz
•
Professional Development
20 questions
Congruent and Similar Triangles

Quiz
•
8th Grade
25 questions
Triangle Inequalities

Quiz
•
10th - 12th Grade