Sanitation Systems phase 1 1.2

Sanitation Systems phase 1 1.2

Professional Development

15 Qs

quiz-placeholder

Similar activities

Wholesale teszt F csoport

Wholesale teszt F csoport

Professional Development

15 Qs

PSRA Corona Quizz Game

PSRA Corona Quizz Game

8th Grade - Professional Development

12 Qs

Consoliditation des connaissances préalables

Consoliditation des connaissances préalables

Professional Development

18 Qs

LA TALLADA DE CABELL

LA TALLADA DE CABELL

Professional Development

16 Qs

Hygiène des mains

Hygiène des mains

Professional Development

11 Qs

level 3 mock test

level 3 mock test

Professional Development

19 Qs

Sanitation System Quiz 1

Sanitation System Quiz 1

Professional Development

10 Qs

le mastic

le mastic

Professional Development

10 Qs

Sanitation Systems phase 1 1.2

Sanitation Systems phase 1 1.2

Assessment

Quiz

Other

Professional Development

Hard

Created by

Daniel Edwards

Used 11+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What kind of bend should be installed at the foot of the stack?

A short radius bend

A long radius bend

A 90-degree bend

A 180-degree bend

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where should access to any stack be provided?

Above the spill over level of the highest appliance

At the same level as the highest appliance

At the base of the stack

Below the spill over level of the highest appliance

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Rule 6 states that the stack should not reduce in size where?

At the top of the stack

In the middle of the stack

In the direction of flow

At the base of the stack

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A branch connection to a stack that is opposite a connection is not allowed at what distance vertically?

Within 50mm

Within 100mm

Within 150mm

Within 200mm

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be fitted to stacks with excessive waste pipe lengths?

Extra ventilation

A smaller diameter stack

A larger diameter stack

A secondary drain

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum capacity for a stack with a size of 50mm?

2.1 l/sec

5.3 l/sec

1.2 l/sec

3.4 l/sec

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum capacity for a stack with a size of 65mm?

1.2 l/sec

2.1 l/sec

3.4 l/sec

5.3 l/sec