Domestic Gas Ventilation Quiz

Domestic Gas Ventilation Quiz

Professional Development

10 Qs

quiz-placeholder

Similar activities

KOMPUTER DASAR

KOMPUTER DASAR

12th Grade - Professional Development

15 Qs

Daily General Knowledge Quiz- Part 4, Mathematics

Daily General Knowledge Quiz- Part 4, Mathematics

3rd Grade - Professional Development

10 Qs

GDCD HK1 11

GDCD HK1 11

Professional Development

15 Qs

Avaliação Pensamento Computacional - Prático

Avaliação Pensamento Computacional - Prático

1st Grade - Professional Development

10 Qs

Extreme Environment and Biofilm - MicroCore Review Center

Extreme Environment and Biofilm - MicroCore Review Center

University - Professional Development

10 Qs

Chemisty Reaction

Chemisty Reaction

Professional Development

10 Qs

Desgloses Farmacología

Desgloses Farmacología

Professional Development

15 Qs

Kajko i Kokosz szkoła latania

Kajko i Kokosz szkoła latania

Professional Development

11 Qs

Domestic Gas Ventilation Quiz

Domestic Gas Ventilation Quiz

Assessment

Quiz

Science

Professional Development

Practice Problem

Medium

Created by

John Flower

Used 10+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When converting Gross heat input to net heat input you must?

Multiply by 1.11.

Divide by 1.11.

Divide by 1.09.

Multiply by 1.08.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the equivalent net kW figure for adventitious air?

14 kW.

28 kW.

1.11 kW.

7 kW.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When calculating compartment ventilation we must not make any allowances for?

For low level ventilation.

For high level ventilation.

For adventitious ventilation.

All of the above.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the smallest size of opening allowed in a vent used for supplying combustion air?

5 mm.

6 mm.

9 mm.

10 mm.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Vents supplying combustion air to a gas fired appliance passing through a cavity wall must be?

At least 100 mm2 cross sectional area.

Sleeved/ducted throughout the width of the wall.

Painted yellow ochre to identify it as a gas vent.

At least 50% larger than the actual requirement.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If a gas cooker requires ventilation it must be?

Provided at high and low levels within the same room as the cooker.

Sized in accordance the manufacturer's instructions or BS 5440-2.

Provided indirectly so as to reduce draughts.

Sized in accordance with BS 5440-1.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When determining the ventilation requirements for an open flued gas appliance within a room, it is derived from?

Heat input gross - 7 x 5 (cm2/kW).

Heat input net - 7 x 4.5 (cm2/kW).

Heat input net - 7 x 5 (cm2/kW).

Heat input gross - 7 x 4.5 (cm2/kW).

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?