HVAC 104

HVAC 104

Professional Development

20 Qs

quiz-placeholder

Similar activities

PowerPoint

PowerPoint

10th Grade - Professional Development

19 Qs

tobots

tobots

KG - Professional Development

22 Qs

Fundamental of Common Rail Diesel Fuel System

Fundamental of Common Rail Diesel Fuel System

University - Professional Development

15 Qs

Scratch: Events, Loops and The Coordinate System

Scratch: Events, Loops and The Coordinate System

2nd Grade - Professional Development

15 Qs

BCS System & Architecture Quiz 7

BCS System & Architecture Quiz 7

University - Professional Development

20 Qs

VEHICLE PARTS (Pre-test)

VEHICLE PARTS (Pre-test)

1st Grade - Professional Development

20 Qs

Gamificación POWER POINT 2-1

Gamificación POWER POINT 2-1

Professional Development

15 Qs

Opeltreffen 2019 (2)

Opeltreffen 2019 (2)

Professional Development

20 Qs

HVAC 104

HVAC 104

Assessment

Quiz

Instructional Technology

Professional Development

Medium

Created by

Jamey Amparo

Used 5+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A TXV with a liquid charged bulb is usually limited to ____________.

high temperature applications

applications where the ambient air temperature stays above freezing

applications that have a narrow operating range

systems that operate below atmospheric pressure

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary function of a TXV in a refrigeration system?

To control the flow of refrigerant into the evaporator

To control the temperature of the refrigerant

To control the pressure of the refrigerant

To control the humidity of the refrigerant

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What could be a possible issue if a TXV is not properly adjusted?

The refrigerant flow could be too high, causing the evaporator to flood

The refrigerant flow could be too low, causing the evaporator to starve

Both A and B

None of the above

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of charge is used in a TXV with a gas charged bulb?

High temperature applications

Applications where the ambient air temperature stays above freezing

Applications that have a narrow operating range

Systems that operate below atmospheric pressure

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The spring tension on a TXV is factory set for a predetermined superheat of _____ °F.

8-12

10-20

3-6

8-16

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Any evaporator that operates below 32°F ______________.

needs a thermostat

does not need defrost

requires some form of defrost

no such thing

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Refrigerant relief valves come in two different types, ___________.

spring loaded and double tap

Spring loaded and one time

fixed or variable

expensive and cheap

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?