HVAC 104

HVAC 104

Professional Development

20 Qs

quiz-placeholder

Similar activities

Meeting Quiz 02.06.2025

Meeting Quiz 02.06.2025

Professional Development

25 Qs

Geothermal Energy Quiz

Geothermal Energy Quiz

Professional Development

20 Qs

AUT 101 Chapter 14 Test week 3/4

AUT 101 Chapter 14 Test week 3/4

Professional Development

20 Qs

Combination Quiz 2

Combination Quiz 2

Professional Development

20 Qs

Air Brakes Quiz 1

Air Brakes Quiz 1

Professional Development

25 Qs

Nissan Engine Management System - Post Test

Nissan Engine Management System - Post Test

Professional Development

15 Qs

5.1 run a program

5.1 run a program

Professional Development

19 Qs

HVAC 104

HVAC 104

Assessment

Quiz

Instructional Technology

Professional Development

Medium

Created by

Jamey Amparo

Used 5+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A TXV with a liquid charged bulb is usually limited to ____________.

high temperature applications

applications where the ambient air temperature stays above freezing

applications that have a narrow operating range

systems that operate below atmospheric pressure

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary function of a TXV in a refrigeration system?

To control the flow of refrigerant into the evaporator

To control the temperature of the refrigerant

To control the pressure of the refrigerant

To control the humidity of the refrigerant

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What could be a possible issue if a TXV is not properly adjusted?

The refrigerant flow could be too high, causing the evaporator to flood

The refrigerant flow could be too low, causing the evaporator to starve

Both A and B

None of the above

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of charge is used in a TXV with a gas charged bulb?

High temperature applications

Applications where the ambient air temperature stays above freezing

Applications that have a narrow operating range

Systems that operate below atmospheric pressure

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The spring tension on a TXV is factory set for a predetermined superheat of _____ °F.

8-12

10-20

3-6

8-16

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Any evaporator that operates below 32°F ______________.

needs a thermostat

does not need defrost

requires some form of defrost

no such thing

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Refrigerant relief valves come in two different types, ___________.

spring loaded and double tap

Spring loaded and one time

fixed or variable

expensive and cheap

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?