Electrical Installation Testing and Inspection

Electrical Installation Testing and Inspection

Professional Development

20 Qs

quiz-placeholder

Similar activities

Electrical principles for plumbers

Electrical principles for plumbers

Professional Development

20 Qs

Cannock inspection and Testing 2

Cannock inspection and Testing 2

Professional Development

19 Qs

Worldskills IC HSE

Worldskills IC HSE

Professional Development

15 Qs

ICIT: Electrical Final Circuit and Wiring system

ICIT: Electrical Final Circuit and Wiring system

Professional Development

20 Qs

Session 3 Symptoms of electrical faults.

Session 3 Symptoms of electrical faults.

Professional Development

20 Qs

Communications 6035-02

Communications 6035-02

Professional Development

24 Qs

Outcome 4 Safe working procedures during fault finding.

Outcome 4 Safe working procedures during fault finding.

Professional Development

20 Qs

 Test de connaissances en électricité

Test de connaissances en électricité

Professional Development

20 Qs

Electrical Installation Testing and Inspection

Electrical Installation Testing and Inspection

Assessment

Quiz

Other

Professional Development

Medium

Created by

Richard Macharia

Used 5+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What are the types of tests used in electrical installation testing and inspection?

Resistance testing, capacitance testing, inductance testing

Continuity testing, insulation resistance testing, earth loop impedance testing, polarity testing, and RCD testing

Voltage testing, current testing, power testing

Frequency testing, phase testing, harmonics testing

2.

OPEN ENDED QUESTION

3 mins • 1 pt

What is the purpose of continuity testing in electrical installation testing?

Evaluate responses using AI:

OFF

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Explain the concept of insulation resistance testing in electrical installation testing.

Insulation resistance testing is used to measure the resistance of insulation materials in electrical installations.

Insulation resistance testing is used to measure the temperature of insulation materials in electrical installations.

Insulation resistance testing is used to measure the current flowing through insulation materials in electrical installations.

Insulation resistance testing is used to measure the voltage of insulation materials in electrical installations.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the significance of earth loop impedance testing in electrical installation testing?

Earth loop impedance testing is only significant for small electrical systems.

Earth loop impedance testing is not significant in electrical installation testing.

Earth loop impedance testing is significant in electrical installation testing because it helps ensure the safety and effectiveness of the electrical system.

Earth loop impedance testing is only significant for commercial electrical systems.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Describe the procedure for testing the polarity of electrical installations.

Connect a polarity tester or multimeter to the circuit or outlet and check for correct or reversed polarity.

Use a voltmeter to measure the voltage of the electrical installation.

Check the color coding of the wires to determine the polarity.

Observe the direction of the current flow in the circuit to determine the polarity.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of RCD testing in electrical installation testing?

To test the resistance of electrical wires in installations.

To ensure the proper functioning of Residual Current Devices (RCDs) in electrical installations.

To check the insulation of electrical components in installations.

To measure the voltage output of electrical devices in installations.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Explain the importance of visual inspection in electrical installation testing.

Visual inspection is important in electrical installation testing because it allows for the identification of any visible defects, damage, or improper installations.

Visual inspection is only needed for new electrical installations.

Visual inspection is only necessary for small electrical installations.

Visual inspection is not important in electrical installation testing.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?