Cannock inspection and Testing 2

Cannock inspection and Testing 2

Professional Development

19 Qs

quiz-placeholder

Similar activities

transformers week 4 review

transformers week 4 review

Professional Development

17 Qs

PCOC - Chapter 3 Review

PCOC - Chapter 3 Review

Professional Development

20 Qs

IE

IE

Professional Development

19 Qs

L3 YR2 Revision 3 (Cold 3)

L3 YR2 Revision 3 (Cold 3)

Professional Development

20 Qs

Pedia MODULE 1 - Group 2

Pedia MODULE 1 - Group 2

Professional Development

20 Qs

First and second party damage prevention during excavation

First and second party damage prevention during excavation

Professional Development

15 Qs

3005 MEN, SELV, PELV MEN & Earthing True False Quiz

3005 MEN, SELV, PELV MEN & Earthing True False Quiz

Professional Development

20 Qs

ECA FOR READMIT

ECA FOR READMIT

Professional Development

20 Qs

Cannock inspection and Testing 2

Cannock inspection and Testing 2

Assessment

Quiz

Other

Professional Development

Medium

Created by

Paul Hussey

Used 36+ times

FREE Resource

19 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

OSG gives the maximum stable value of Ze for a TT installation as

100 ohms

21 ohms

0.8 ohms

200 ohms

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Safe isolation should be carried out by

A Skilled person

An engineer

The home owner

The client

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which type of earthing system relies on a separately supplied earth, usually the sheathing on the cable

TT

TN-S

TN-C-S

IT

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which of the following would not be one of the human senses to use during the

initial verification of an addition to a lighting circuit:

smell

taste

sight

hearing

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The person carrying out inspection and testing must have

An On site guide

A Megger

Sound knowledge and experience relevant to the installation being inspected

A decent van

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The top surface of a consumer unit should be protected from ingress of dust to a standard of

IP4X

IP2X

IPX4

IPX2

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

A visual inspection is necessary

before testing to check whether

The ZS is within the maximum allowed

Switch gear is accessible

The insulation resistance is acceptable

RCD testing is acceptable