Review 4-6

Review 4-6

University

10 Qs

quiz-placeholder

Similar activities

Series and Parallel Circuits Quiz

Series and Parallel Circuits Quiz

University

11 Qs

Transformer Quiz

Transformer Quiz

University

10 Qs

Basic Indicating Instrument

Basic Indicating Instrument

KG - University

10 Qs

Formative Assessment : Topic 5

Formative Assessment : Topic 5

University

10 Qs

Review Basic Circuit

Review Basic Circuit

University

12 Qs

AC Drive Characteristics 1

AC Drive Characteristics 1

9th Grade - Professional Development

10 Qs

Induced emf

Induced emf

12th Grade - University

11 Qs

Quiz: Ohm's Law

Quiz: Ohm's Law

University

15 Qs

Review 4-6

Review 4-6

Assessment

Quiz

Physics

University

Hard

NGSS
MS-PS1-4, HS-PS3-4, MS-PS3-3

+1

Standards-aligned

Created by

Robert Hemmila

Used 3+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Meters used in the HVAC industry?

Are only analog.

Measure only one charecteristic of a circuit.

Usually measure multiple charecteristics like voltage, amps, ohms and often more.

Are not able to measure voltage.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A single pole double throw switch is able to?

Connect a common point to either one of the two poles depending on the position.

Energize 2 loads at the same time.

Double the voltage throw to the loads.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An open on rise pressure switch

Is shown with the switch blade above the dot on the end.

is shown with the switch blade below the dot on the end.

Is shown with the switch blade not touching either end.

Is not important

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An open on rise thermostat is used for?

Refrigeration

Air conditioning

Heating

An indicator lamp

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A closes on rise thermostat is used for ?

Heating

Air conditioning

Fan control

Both b and C

Tags

NGSS.MS-PS1-4

NGSS.MS-PS3-3

NGSS.MS-PS3-4

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A contactor used for residential AC condensing units ?

Single pole 208 volt coil

Double pole 120 volt coil

Double pole 24 volt coil

triple pole 208 volt coil

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The line voltage to the condensing unit in a residential system is?

24 volts

120 volts

240 volts

480 volts