BUILDING 121 - 160

BUILDING 121 - 160

Professional Development

40 Qs

quiz-placeholder

Similar activities

Rosary Quiz

Rosary Quiz

KG - Professional Development

37 Qs

super sabado jas

super sabado jas

KG - Professional Development

41 Qs

Números (El Viaje hacia la Tierra Prometida) 1ra. Parte

Números (El Viaje hacia la Tierra Prometida) 1ra. Parte

Professional Development

41 Qs

Kuiz Maulid Nabi SMK Pedas 2024 - Kategori Guru

Kuiz Maulid Nabi SMK Pedas 2024 - Kategori Guru

Professional Development

40 Qs

VHF Bible Quiz 2023

VHF Bible Quiz 2023

Professional Development

36 Qs

October 2019 General Conference

October 2019 General Conference

KG - Professional Development

37 Qs

QUIZ PERINGATAN MAULID Nabi Muhammad SAW 1446 H

QUIZ PERINGATAN MAULID Nabi Muhammad SAW 1446 H

Professional Development

45 Qs

TA MODUL 4

TA MODUL 4

Professional Development

40 Qs

BUILDING 121 - 160

BUILDING 121 - 160

Assessment

Quiz

Religious Studies

Professional Development

Easy

Created by

Fernando Lop

Used 7+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

40 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following types of safety glazing materials shall not be solely identified by a certificate or affidavit?

laminated glass

tempered glass

wired glass

plastic glazing

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following fire-rated glazing markings is required for a sidelight adjacent to a 1-hour corridor fire door assembly?

D-H-45

D-H-O-H-20

D-H-O-H-45

W-60

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When a covered mall building exceeds ____________ square feet an emergency voice/alarm communication system shall be provided.

50,000

44 inches

72 inches

96 inches

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where a smoke control system is required and the exhaust method is utilized, what is the minimum height at which the smoke layer interfaced must be maintained above the means of egress walking surface?

6 feet, 0 inches

7 feet, 6 inches

7 feet, 0 inches

6 feet, 8 inches

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a fully sprinklered Type IIB building where the fire separation distance is 12 feet, the maximum allowable area of protected exterior wall openings is _______________.

15 percent

25 percent

45 percent

60 percent

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Penetrations in _______________ shall be tested for air leakage in accordance with the requirements of UL 1479.

smoke partitions

smoke barriers

fire barriers

fire walls

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a nonsprinklered building, any single opening in a fire barrier is limited to a maximum area of _______________ square feet.

20

100

120

156

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?