BUILDING 121 - 160

BUILDING 121 - 160

Professional Development

40 Qs

quiz-placeholder

Similar activities

Bible Quiz

Bible Quiz

KG - Professional Development

42 Qs

Gospel of Mark

Gospel of Mark

Professional Development

38 Qs

Greek and Roman Mythology

Greek and Roman Mythology

KG - Professional Development

40 Qs

Book of Daniel

Book of Daniel

Professional Development

35 Qs

IC 85 - 126

IC 85 - 126

Professional Development

42 Qs

GGG HARD ll

GGG HARD ll

Professional Development

41 Qs

DDD

DDD

Professional Development

43 Qs

Bible Legends

Bible Legends

Professional Development

41 Qs

BUILDING 121 - 160

BUILDING 121 - 160

Assessment

Quiz

Religious Studies

Professional Development

Easy

Created by

Fernando Lop

Used 7+ times

FREE Resource

40 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following types of safety glazing materials shall not be solely identified by a certificate or affidavit?

laminated glass

tempered glass

wired glass

plastic glazing

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following fire-rated glazing markings is required for a sidelight adjacent to a 1-hour corridor fire door assembly?

D-H-45

D-H-O-H-20

D-H-O-H-45

W-60

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When a covered mall building exceeds ____________ square feet an emergency voice/alarm communication system shall be provided.

50,000

44 inches

72 inches

96 inches

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where a smoke control system is required and the exhaust method is utilized, what is the minimum height at which the smoke layer interfaced must be maintained above the means of egress walking surface?

6 feet, 0 inches

7 feet, 6 inches

7 feet, 0 inches

6 feet, 8 inches

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a fully sprinklered Type IIB building where the fire separation distance is 12 feet, the maximum allowable area of protected exterior wall openings is _______________.

15 percent

25 percent

45 percent

60 percent

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Penetrations in _______________ shall be tested for air leakage in accordance with the requirements of UL 1479.

smoke partitions

smoke barriers

fire barriers

fire walls

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a nonsprinklered building, any single opening in a fire barrier is limited to a maximum area of _______________ square feet.

20

100

120

156