MEC522/MEM686 CONTROL SYSTEM QUIZ 1

MEC522/MEM686 CONTROL SYSTEM QUIZ 1

University

10 Qs

quiz-placeholder

Similar activities

control system

control system

University

10 Qs

QUIZ 2 MEM685

QUIZ 2 MEM685

University

10 Qs

IDA_Quiz-01

IDA_Quiz-01

University

11 Qs

IS QUIZ FOR BSIE 2

IS QUIZ FOR BSIE 2

University

15 Qs

Control system - open & closed loop

Control system - open & closed loop

University

8 Qs

control system

control system

University

15 Qs

Quiz 1 MEC522 Oct 2022/23

Quiz 1 MEC522 Oct 2022/23

University

10 Qs

CE Quiz 4 - Linear Approximation of the Non-Linear System

CE Quiz 4 - Linear Approximation of the Non-Linear System

University

15 Qs

MEC522/MEM686 CONTROL SYSTEM QUIZ 1

MEC522/MEM686 CONTROL SYSTEM QUIZ 1

Assessment

Quiz

Other

University

Easy

Created by

nurul noor

Used 2+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Control of an industrial process by automatic rather than manual means is often called .................. [CO1/PO1]

a design gap

negative feedback

automation

a specification

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An open-loop control system utilizes an actuating device to control a process ___________ [CO1/PO1]

in engineering synthesis

using feedback

without using feedback

in engineering design

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Closed-loop control systems should have which of the following properties: [CO1/PO1]

Low sensitivity to changes in the plant parameters

Good regulation against disturbances

Desirable responses to commands

All of the above

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The function of the proportional mode is to ____________? [CO1/PO1]

Provide gain

Eliminate offsets

To speed up the response and minimize the overshoot

All of the above

Answer explanation

The proportional mode is used for small set points and small load changes

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The PID controller is very effective for _____________ processes. [CO1/PO1]

Slower

Faster

Poor

None of the above

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following controllers improves steady state error and also stability of the system? [CO1/PO1]

P controller

PI controller

Both a and b

None of the above

Answer explanation

The PI controller reduces the steady state error

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the disadvantage of proportional integral controller? [CO1/PO1]

Reduces steady state error

Increases the order of system

System will be less stable

None of the above

Answer explanation

The advantages of proportional integral controller is it reduces steady state error and increases the order of the system

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?