Testing of insulators.

Testing of insulators.

University

5 Qs

quiz-placeholder

Similar activities

Thompson ch 9

Thompson ch 9

University

10 Qs

epithelium

epithelium

University

10 Qs

Communication Tools

Communication Tools

University

10 Qs

Atomic structure

Atomic structure

KG - Professional Development

10 Qs

HAMMER THROW

HAMMER THROW

4th Grade - Professional Development

10 Qs

EC8691 - MICROPROCESSORS AND MICROCONTROLLERS

EC8691 - MICROPROCESSORS AND MICROCONTROLLERS

University

10 Qs

BANK MANAGEMENT & FINANCIAL SERVICES

BANK MANAGEMENT & FINANCIAL SERVICES

University

10 Qs

Group A_Danone

Group A_Danone

University - Professional Development

10 Qs

Testing of insulators.

Testing of insulators.

Assessment

Quiz

Education

University

Practice Problem

Hard

Created by

KEERTHANA S

Used 1+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

5 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

What is the purpose of testing insulators?

To ensure that the insulators are properly installed
To identify any defects in the insulators
To prevent the accumulation of dust on the insulators
To check the alignment of the transmission line

2.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

Which of the following tests is used to determine the puncture voltage of an insulator?

Thermal stability test
Porosity test
Power frequency voltage test
Corona test

3.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

What is the purpose of conducting a radio interference voltage (RIV) test on insulators?

To detect any partial discharges occurring in the insulators
To measure the frequency response of the insulators
To determine the flashover voltage of the insulators
To evaluate the performance of the insulators under high humidity conditions

4.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

Which of the following tests is used to determine the wet flashover voltage of an insulator?

High voltage test
Power frequency voltage test
Wet power frequency voltage test
Dry power frequency voltage test

5.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

What is the recommended maximum value of the leakage current for insulators under test conditions?

5 mA
10 mA
15 mA
20 mA

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?

Discover more resources for Education