PEC 3

PEC 3

University

50 Qs

quiz-placeholder

Similar activities

LKS MOTORCYCLE 2025

LKS MOTORCYCLE 2025

11th Grade - University

50 Qs

Master Minds Quiz

Master Minds Quiz

University

50 Qs

Structural NSCP Quiz

Structural NSCP Quiz

University

50 Qs

Self-Consolidating Concrete Testing Concepts

Self-Consolidating Concrete Testing Concepts

University

51 Qs

Tennez

Tennez

12th Grade - University

50 Qs

Kuis akhir 2

Kuis akhir 2

10th Grade - University

49 Qs

Exa-T2

Exa-T2

University

45 Qs

PROFESSIONAL PRACTICE 02

PROFESSIONAL PRACTICE 02

University

50 Qs

PEC 3

PEC 3

Assessment

Quiz

Other

University

Hard

Created by

Lira Ortega

FREE Resource

50 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An assembly drawing for a switchboard appears to have some errors. As supervisor, what steps will your take?

report the apparent error to your supervisor.

make the connection per drawing but be prepared to correct it if orders.

hold the job until you have checked with the person who installed the plans.

proceeds making the corrections on the drawing.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Branch circuit conductors supplying a single-phase motor shall have an ampacity NOT exceeding

100%

125%

200%

115%

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Flat conductor cables maybe installed in any of the following locations Except one. Which one of this?

in wet locations

in damp locations

on hard concrete flooring

for branch circuits

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For the installations of 2.0 mm² conductors in 600-volts circuits. What is the minimum insulation resistance allowed by the Philippine Electrical code?

500,000 ohms

1,000,000 ohms

750,000 ohms

250,000 ohms

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The following are types of protection for single pase induction motors, EXCEPT

overload protection

ground fault protection

under voltage protection

single phase protection

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The Philippine Electrical Code, Part 1 does not cover wiring of equipment installed within or to or from one of the following. Which is one is this?

trailers

Mobile Homes

water crafts

airplanes

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Vertical clearances of all service drop conductors above roofs shall NOT be less than one of the following values.

2,000 mm

2,750 mm

3,000 mm

2,500 mm