HVAC FC 08

HVAC FC 08

Professional Development

66 Qs

quiz-placeholder

Similar activities

Quiz

Quiz

KG - Professional Development

65 Qs

HVAC FC 02

HVAC FC 02

Professional Development

70 Qs

HVAC FC 07

HVAC FC 07

Professional Development

70 Qs

Applied Mechanics - Second 62 Q

Applied Mechanics - Second 62 Q

Professional Development

63 Qs

18th Edition complete mock 2

18th Edition complete mock 2

Professional Development

61 Qs

MCQ- OIC751 TRANSDUCER ENGINEERING

MCQ- OIC751 TRANSDUCER ENGINEERING

Professional Development

61 Qs

Unit-6 Mechanical Components

Unit-6 Mechanical Components

Professional Development

67 Qs

MASTER OPEN BOOK EXAM 2

MASTER OPEN BOOK EXAM 2

Professional Development

70 Qs

HVAC FC 08

HVAC FC 08

Assessment

Quiz

Other

Professional Development

Medium

Created by

Johnny Thulin

Used 3+ times

FREE Resource

66 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image
When any Group 1 refrigerant, except CO2, is removed from a refrigerating system how shall it be discharged?

to the atmosphere at an approved location

from the high pressure side of the refrigerating system to the low pressure side

into an approved shipping container

into an empty disposable container

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image
A zero energy consuming device could be one of the following:

Pneumatic solenoid

A thermocouple

Mechanical relay

Solid state (electromechanical) controller

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where a closet is designed for the installation of a clothes dryer, an opening having an area of not less than ___ for makeup air shall be provided in the closet enclosure.

40 square inches

65 square inches

80 square inches

100 square inches

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image
The _____ thermostat wire is the one approved to pass through air ducts.

smoke-rated

fire-rated

plenum-rated

shock-rated

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The minimum dimension of a horizontal duct that is used to introduce combustion air into a confined space must NOT be less than
1 inch
2 inches
3 inches
5 inches

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Give details on how a natural gas piping tracer must be installed. It must:
have the radius of bends not less than 20 times the inside diameter.
have the pipe joints threaded and screwed together
include a minimum 18 AWG insulated copper tracer
be laid on a bed of pea gravel

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Enthalpy is the
total heat of a substance.
total latent heat of a substance.
total sensible heat of a substance.
measured temperature difference of two substances.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?