PE 1 Practice Test HVAC

PE 1 Practice Test HVAC

Professional Development

105 Qs

quiz-placeholder

Similar activities

Long Quiz Fire technology and arson Inv.

Long Quiz Fire technology and arson Inv.

Professional Development

100 Qs

TES WAWASAN KEBANGSAAN- BHINNEKA TUNGGAL IKA

TES WAWASAN KEBANGSAAN- BHINNEKA TUNGGAL IKA

Professional Development

108 Qs

Advanced radiographic

Advanced radiographic

University - Professional Development

100 Qs

TRYOUT

TRYOUT

Professional Development

100 Qs

2018 State Test Simulation Version 1

2018 State Test Simulation Version 1

Professional Development

100 Qs

D4(RAH) APPLIED MECHANICS MASTER THE DAY

D4(RAH) APPLIED MECHANICS MASTER THE DAY

Professional Development

100 Qs

BANKING LAW AND PRACTICE QUIZ

BANKING LAW AND PRACTICE QUIZ

Professional Development

102 Qs

Nursing Practice 3

Nursing Practice 3

Professional Development

100 Qs

PE 1 Practice Test HVAC

PE 1 Practice Test HVAC

Assessment

Quiz

Professional Development

Professional Development

Hard

Created by

Johnny Thulin

FREE Resource

105 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum operating pressure in an air duct system
.5 in wc
2.0 in wc
6.0 in wc
10 in wc
603.3 IMC

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A 2000 sq. ft. Type II dry cleaning system shall be provided with an exhaust no less than:
1500
2000
3000
4000
502.6.1 IMC

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Combustion air ducts shall have a min. cross sectional dimension of:
1.5"
2"
2.5"
3"
304.6 IFGC

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A bathroom in a dwelling unit must be provided with a minimum intermittent exhaust of:
A. 15 cfm
25 cfm
40 cfm
50 cfm
T403.3.2.3 IMC

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A hot water heater boiler with a 5,000,000 BTU/Hr input shall have what minimum clearance from the top of the boiler to the ceiling?
2'
3'
7'
10'
T1004.3.1 IMC

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A 150,000 BTU residential furnace is located in a confined space where combustion is drawn from the outdoors through horizontal ducts. The minimum area for each of the 2 openings is:
38 sq. in
75 sq. in
150 sq. in
100 sq. in
304.6.1 Horiz. Use 2k IFGC

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A heater installed in a public garage must be installed a minimum distance above the floor.
5'
7'
8'
10'
304.6 IMC