MR Random 2

MR Random 2

Professional Development

30 Qs

quiz-placeholder

Similar activities

Pre-MiyerQUIZles_Nov

Pre-MiyerQUIZles_Nov

Professional Development

25 Qs

6035 8202 Hot water systems

6035 8202 Hot water systems

Professional Development

30 Qs

Product Knowledge Mercy Actros

Product Knowledge Mercy Actros

University - Professional Development

25 Qs

CERTIFICATION OF SERVICE TECHNICIAN PROGRAM (CSTP)

CERTIFICATION OF SERVICE TECHNICIAN PROGRAM (CSTP)

Professional Development

25 Qs

Unit 38

Unit 38

Professional Development

27 Qs

core java 2

core java 2

Professional Development

25 Qs

cylinder head

cylinder head

Professional Development

32 Qs

ACR 101 Unit 3

ACR 101 Unit 3

Professional Development

26 Qs

MR Random 2

MR Random 2

Assessment

Quiz

Professional Development

Professional Development

Medium

Created by

Johnny Thulin

Used 4+ times

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Diminishing quality of indoor air is due to --·
reduced infiltration of outdoor air
vapors released from new building materials
Both A and B.
Neither A nor B.
529

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Resistance is measured in
Coulombs
amperes
ohms
farads
225

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

How can the refrigerant temperature in an air-cooled condenser be estimated?
By adding 30°F to 35°F to the ambient temperature of air around the condenser
By subtracting 25°F from the present condenser temperature
By placing a temperature probe inside the suction line
None of the above.
153

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which instrument measures only the true power consumed by an electrical load?
Power factor meter
Wattmeter
Voltmeter
Ohmmeter
365

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The total recovery cylinder weight is equal to the maximum refrigerant weight plus the __of the cylinder.
specific gravity
water weight
tare weight
density
204

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which of the following statements regarding a low-side float system is not true?
The evaporator has a large receiver that holds liquid refrigerant.
The float can be a sealed ball or an open pan.
The high-side and low-side pressures balance during the Off cycle.
These systems are often referred to as flooded systems.
417

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which of the following is the best test a technician can perform to see if the thermostat is the cause of a no-start condition?
Bypass the thermostat. If the system does not start, the problem is in the thermostat.
Bypass the thermostat. If the system starts, the problem is in the thermostat.
Turn the thermostat to its highest setting. If the system does not start, the problem is in the thermostat.
Turn the thermostat to its lowest setting. If the system does not start, the problem is in the thermostat.