Fault finding NETK3/7

Fault finding NETK3/7

Professional Development

35 Qs

quiz-placeholder

Similar activities

kep1er !

kep1er !

KG - Professional Development

30 Qs

Food and Drink

Food and Drink

KG - Professional Development

30 Qs

CRT_Aptitude_Prep

CRT_Aptitude_Prep

Professional Development

39 Qs

Ardour Mentorship Quiz

Ardour Mentorship Quiz

Professional Development

32 Qs

GIVE AWAY

GIVE AWAY

Professional Development

30 Qs

Olympics 2020 Quiz

Olympics 2020 Quiz

6th Grade - Professional Development

30 Qs

Logo Quiz

Logo Quiz

KG - Professional Development

35 Qs

Roblox

Roblox

KG - Professional Development

40 Qs

Fault finding NETK3/7

Fault finding NETK3/7

Assessment

Quiz

Fun

Professional Development

Easy

Created by

Paul Hussey

Used 67+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

35 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

An operative carrying out fault diagnosis would not need to be familiar with:

supply earthing system

schedule of test results

repair cost

voltage present

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which of the following would not be required in a fault finding sequence:

time repair will take

safe isolation

testing

analysis of results

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

A continuity test as part of fault diagnosis would be carried out with which instrument:

earth-fault loop impedance tester

high resistance ohmmeter

low resistance ohmmeter

RCD tester

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

A loose termination could cause the following

short circuit between live conductors

overcurrent

arcing

operation of the protective device

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The guidance for test leads used on instruments is contained in

BS 7671

EAWR

HASAWA

GS38

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which dead test would be carried out during intial fault diagnosis

RCD test

insulation resistance

functional

earth-fault loop impedance

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Whilst fault finding you check and discover the BS 3036 fuse protecting the circuit has ruptured with globules of copper spattered over the holder together with black carbon powder. The most likely fault would be:

short circuit

open circuit

loose termination

broken conductor

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?