Module 7 Review

Module 7 Review

12th Grade

10 Qs

quiz-placeholder

Similar activities

Girl Scout Cookie Quiz

Girl Scout Cookie Quiz

KG - 12th Grade

15 Qs

Postharvest Processing, Conditioning, and Storage

Postharvest Processing, Conditioning, and Storage

9th - 12th Grade

14 Qs

The Big Cat Quiz

The Big Cat Quiz

KG - Professional Development

10 Qs

Battle of the WITS - EASY ELIMINATIONS

Battle of the WITS - EASY ELIMINATIONS

4th - 12th Grade

10 Qs

9.3 Quiz

9.3 Quiz

9th - 12th Grade

10 Qs

Anitha and the honeybees

Anitha and the honeybees

KG - Professional Development

10 Qs

The Multiplication Rules and Conditional Probability

The Multiplication Rules and Conditional Probability

10th Grade - University

10 Qs

shipping and receiving tools

shipping and receiving tools

9th - 12th Grade

10 Qs

Module 7 Review

Module 7 Review

Assessment

Quiz

Other

12th Grade

Medium

Created by

Tylor Brown

Used 21+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

According to NEC Section 210.52, laundry areas require at least _____.

one receptacle

two receptacles

three receptacles

four one receptacle

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

What size of a junction box must be used if there is one 4" conduit and two 3" conduits entering on one side of the box and exiting at a 90° angle on another side of the box?

(Assume the conductor size is No. 4 AWG or larger.)

30"

48"

56"

60"

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Two wires enter a box, are each connected to a terminal, and then exit again. The total conductor count is _____.

1

2

3

4

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which of the following is true regarding the installation of pull boxes?

They are rarely worth the extra effort and expense.

Pull boxes should be inaccessible for safety purposes.

Properly placed pull boxes reduce conductor strain during a pull.

Pull boxes should be located above the finished ceiling whenever possible.

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which of the following counts as two conductors when used in a box?

Each fixture stud

Each looped conductor over 6"

Each looped conductor over 12"

Each cable clamp

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which type of boxes are typically used for wall-mounted lighting fixtures?

Aluminum boxes with threaded hubs

NM device boxes

Handy boxes

Octagon and round boxes

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

When sizing an outlet box, how many conductors must be deducted for a switch?

1

2

3

4