2018 Mechanical Chapter 10

2018 Mechanical Chapter 10

Professional Development

25 Qs

quiz-placeholder

Similar activities

Medical Gas Systems 2021 101-125

Medical Gas Systems 2021 101-125

Professional Development

25 Qs

Post Test Sosialisasi RSD dan HSSE FT Reo

Post Test Sosialisasi RSD dan HSSE FT Reo

Professional Development

20 Qs

Boiler and Steam Technology

Boiler and Steam Technology

Professional Development

21 Qs

AIR CONDITIONER SYSTEM PRE/POST TETS

AIR CONDITIONER SYSTEM PRE/POST TETS

Professional Development

20 Qs

Revision Fluid Mechanics

Revision Fluid Mechanics

Professional Development

21 Qs

2018 IFGC CH 4B

2018 IFGC CH 4B

Professional Development

25 Qs

Calibrator Kit

Calibrator Kit

1st Grade - Professional Development

20 Qs

GMJ 9189 Phase 3 Central heating MCQ

GMJ 9189 Phase 3 Central heating MCQ

Professional Development

20 Qs

2018 Mechanical Chapter 10

2018 Mechanical Chapter 10

Assessment

Quiz

Other

Professional Development

Easy

Created by

Johnny Thulin

Used 5+ times

FREE Resource

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The provisions of IMC Chapter 10 do not apply to which of the following types of appliances or equip.?
boilers
water heaters
medical gas containers
pressure vessels
1001.1, Exception 3

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

An unfired pressure vessel in a Group B occupancy is not regulated by Chapter 10, if it operates at a max. pressure of _ psi and has a max. volume of _ cubic feet.
350, 10
250, 10
350, 5
250, 5
1001.1, Exception 4

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Chapter 10 of the IMC does not apply to any boiler or pressure vessel subject to _ by Federal or State inspectors.
approval
review
inspection
certification
1001.1, Exception 7

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

All water heaters shall be capable of being removed without _.
use of special tools
removing permanent construction
removing doors
special knowledge or effort
1002.1

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Water heaters shall be sized to prevent the space-heating load from reducing the required _.
potable water heating capacity
potable water flow rate
water temperature
water pressure
1002.2.1

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

A temperature-actuated mixing valve shall be provided where a potable water-heating and space-heating system requires water for space heating at a temperature higher than _ ºF.
140
160
180
200
1002.2.2

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Boiler operating instructions of a permanent type shall be _.
kept on file by the fire department
provided to the mechanical inspector
kept on file in the boiler room
attached to the boiler
1004.2

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?