GB.LV.1.1

GB.LV.1.1

Professional Development

15 Qs

quiz-placeholder

Similar activities

M6.11 Cat A

M6.11 Cat A

Professional Development

15 Qs

KOE034: Sensors and Instruments

KOE034: Sensors and Instruments

Professional Development

11 Qs

JNTUH ASSIGNMENT 3

JNTUH ASSIGNMENT 3

Professional Development

10 Qs

Who is Maths Quiz Bee...

Who is Maths Quiz Bee...

Professional Development

10 Qs

Cable and Electrical Safety Quiz

Cable and Electrical Safety Quiz

Professional Development

19 Qs

Electrical Cable Knowledge Quiz

Electrical Cable Knowledge Quiz

Professional Development

20 Qs

NEC branch Circuits

NEC branch Circuits

Professional Development

15 Qs

GB.LV.1.1

GB.LV.1.1

Assessment

Quiz

Mathematics

Professional Development

Medium

Created by

Josef Hosgood

Used 18+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Bonding establishes electrical continuity and ___ between electrical materials required to be electrically connected.

Conductivity

Impedance

Opposition

Resistance

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Electrical systems are grounded to accomplish all but which of the following performance objectives?

Facilitate overcurrent device operation

Limit the voltage due to line surges, or unintentional contact with higher-voltage lines

Limit the voltage imposed by lightning

Stabilize the voltage to ground during normal operation

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The highest current at rated voltage that an overcurrent device is identified to interrupt under standard test conditions best defines which of the following?

Ground fault rating

Interrupting rating

Normal current rating

Short-circuit rating

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Connected to establish continuity and conductivity defines which of the following?

Bonded

Grounded

Grounding

Ungrounded

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A complete lightning protection system includes all but which of the following?

A separate bonding grid

Grounding electrodes and down conductors

Strike termination devices and interconnecting conductors and bonding jumpers

Surge protective devices

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The service grounded neutral conductor of a single phase 3 wire system performs which of the following functions?

Carries line to neutral load current

Connects to the neutral point of the utility supply system

Serves as an effective ground fault current path during ground fault conditions

All of the above

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If an isolated grounding receptacle is installed on a 30-amp branch circuit what is the minimum size required for the isolated/insulated copper equipment grounding conductor?

14awg

12awg

10awg

8awg

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?