SPT02

SPT02

Professional Development

93 Qs

quiz-placeholder

Similar activities

ST CH22

ST CH22

Professional Development

90 Qs

MYFA QUIZ

MYFA QUIZ

Professional Development

93 Qs

Hitha C Quiz 1

Hitha C Quiz 1

Professional Development

96 Qs

Truly Impossible

Truly Impossible

6th Grade - Professional Development

94 Qs

教學方法1~4

教學方法1~4

Professional Development

95 Qs

Cuestionario sobre Alimentos y Valoración del Estado Nutricional

Cuestionario sobre Alimentos y Valoración del Estado Nutricional

Professional Development

90 Qs

SOAL TEKNIS  PENGADMINISTRASI PERKANTORAN 1

SOAL TEKNIS PENGADMINISTRASI PERKANTORAN 1

Professional Development

90 Qs

Explosives and Blasting

Explosives and Blasting

Professional Development

93 Qs

SPT02

SPT02

Assessment

Quiz

Other

Professional Development

Medium

Created by

Johnny Thulin

Used 1+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

93 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Waste Stack Vent minimum 1-1/2" size required receiving the discharge _ DFUs at each of 3 branch intervals
1
2
3
4

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The sign at non-potable water outlets shall have letters at least __________ inch high on a contrasting background.
1"
3/4"
1/2"
3/8"

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Substances that damage the sewer system are prevented from entering the drainage system by __________ .
filters
strainers
traps or backwater valve
interceptors or separators

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

What is the minimum size for a stack vent serving a 21/2-inch waste stack?
1-1/4 inches
1-1/2 inches
2 inches
2-1/2 inches

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

A shower liner must extend __________ inches above the threshold on all sides
2
3
1.5
2.5

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Freezeproof yard hydrants that drain the riser into the ground __________ .
Are prohibited
Are permitted when identified as non potable
Are not considered to be stop and waste valves
Require integral backflow prevention

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

A solvent-cement joint between ABS and PVC plastic piping is __________.
prohibited
permitted in above ground locations only
permitted with yellow primer complying with ASTM D3138
permitted only where the building drain connects to the building sewer

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?