Roman Architecture

Roman Architecture

5th Grade

54 Qs

quiz-placeholder

Similar activities

Test Review Progressives & Women's Suffrage

Test Review Progressives & Women's Suffrage

5th Grade

56 Qs

Southern Africa

Southern Africa

5th - 10th Grade

49 Qs

Ancient Greece HMS

Ancient Greece HMS

5th - 7th Grade

51 Qs

50 State Capitals

50 State Capitals

5th - 8th Grade

51 Qs

Washington, Adams, Jefferson, Madison,War of 1812 & Monroe

Washington, Adams, Jefferson, Madison,War of 1812 & Monroe

5th - 8th Grade

53 Qs

Computing Heroes Quiz KS3

Computing Heroes Quiz KS3

5th - 10th Grade

53 Qs

VS9

VS9

4th - 5th Grade

52 Qs

USI.7

USI.7

5th - 6th Grade

50 Qs

Roman Architecture

Roman Architecture

Assessment

Quiz

History

5th Grade

Medium

Created by

Deven Biediger

Used 14+ times

FREE Resource

54 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Building sewers shall be tested by completely filling the sewer with water from the _

lowest to highest point

lowest to at least a 5-foot head

lowest to at least 10-foot head

lowest to at least ground level

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Except for plastic piping systems, hot and cold water piping may be tested with _

40 psi air or 150 psi water for 10 minutes

35 psi air for at least 15 minutes

50 psi air or the working pressure of the water in the system for at least 15 minutes

100 psi air for at least 10 minutes

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The required clearance in front of a 2-inch cleanout is _ inches.

8

12

18

24

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A stack, as defined in the code, is _

the main vent

and vertical vent

the vertical main of soil, waste, or vent piping that extends one or more stories

the horizontal main of soil, waste, or vent stack

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Under no circumstances may gas appliance pressure regulators be vented _

to the atmosphere

to the combustion chamber near the pilot

to the gas utilization equipment flue or exhaust system

using black iron pipe

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Above ground schedule 40 PVC and ABS DWV plastic piping installed horizontally shall be supported intervals of not to exceed _ feet.

4

6

8

10

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When sizing a copper fuel-gas piping system that has an inlet pressure of less than 2 psi with a pressure drop of 0.3-inch w.c., the maximum cubic feet per hour of gas flow allowed through a 5/8-inch OD. ACR tube 75 feet in developed length is_

13

27

48

68

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?