Quiz 1.3 EM- II

Quiz 1.3 EM- II

University

9 Qs

quiz-placeholder

Similar activities

CONTROL SYSTEM

CONTROL SYSTEM

University

10 Qs

Quiz 1.4 EM-II

Quiz 1.4 EM-II

University

6 Qs

DC Machines

DC Machines

University

12 Qs

EM-II EMF method

EM-II EMF method

University

10 Qs

Electrical Machine I (Summar Class)

Electrical Machine I (Summar Class)

University

10 Qs

control system

control system

University

10 Qs

Synchronous Motor

Synchronous Motor

University

10 Qs

Quiz 2

Quiz 2

University

10 Qs

Quiz 1.3 EM- II

Quiz 1.3 EM- II

Assessment

Quiz

Other

University

Hard

Created by

Dr. Prakash

Used 1+ times

FREE Resource

9 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is NOT a type of synchronous generator?
Salient type
Non-salient type
Induction type
Synchronous type

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the EMF equation used for in a synchronous generator?
Calculating the voltage produced by the generator
Determining the power factor of the system
Measuring the flux distribution in the generator
Determining the efficiency of the generator

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following factors does NOT affect the EMF equation in a synchronous generator?
The number of turns in the winding
The speed of the generator
The strength of the magnetic field
The temperature of the generator

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a synchronous generator, what is the purpose of the armature reaction?
To shift the flux distribution of the generator
To increase the voltage produced by the generator
To decrease the power factor of the system
To increase the efficiency of the generator

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the relationship between the EMF equation and the armature reaction in a synchronous generator?
The EMF equation is affected by the armature reaction
The armature reaction is affected by the EMF equation
Both the EMF equation and the armature reaction are independent of each other
Neither the EMF equation nor the armature reaction are related to each other

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How does the winding factor of a synchronous generator affect the EMF equation?
It does not affect the EMF equation
It increases the EMF equation
It decreases the EMF equation
It depends on the type of winding used

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A synchronous generator has a winding factor of 0.8 and a magnetic field strength of 0.6. The generator is operating at a speed of 1800 RPM. What is the EMF produced by the generator? (Assume that the number of turns in the winding is constant.)
1080 V
1080 kV
0.8 V
0.8 kV

8.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A synchronous generator has a winding factor of 0.9 and a magnetic field strength of 0.7. The generator is operating at a speed of 1500 RPM. What is the EMF produced by the generator? (Assume that the number of turns in the winding is constant.)
1065 V
1065 kV
0.9 V
0.9 kV

9.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A synchronous generator has a winding factor of 0.85 and a magnetic field strength of 0.65. The generator is operating at a speed of 1200 RPM. What is the EMF produced by the generator? (Assume that the number of turns in the winding is constant.)
1020 V
1020 kV
0.85 V
0.85 kV