Residential Wiring Chap. 12

Residential Wiring Chap. 12

12th Grade

30 Qs

quiz-placeholder

Similar activities

3er examen origen y evolucion

3er examen origen y evolucion

12th Grade

25 Qs

REVIEWER

REVIEWER

8th Grade - University

25 Qs

Collision Theory and Rate of Reactions

Collision Theory and Rate of Reactions

11th - 12th Grade

25 Qs

Cat Dissection Muscles

Cat Dissection Muscles

12th Grade - University

25 Qs

Forces and Speed

Forces and Speed

8th Grade - University

25 Qs

Levels of Hierarchy

Levels of Hierarchy

7th Grade - University

25 Qs

Functions of Components in Food

Functions of Components in Food

11th - 12th Grade

25 Qs

IB SEHS 11.0 Skill Acquisition & Analysis

IB SEHS 11.0 Skill Acquisition & Analysis

12th Grade

25 Qs

Residential Wiring Chap. 12

Residential Wiring Chap. 12

Assessment

Quiz

Science

12th Grade

Practice Problem

Medium

NGSS
MS-PS1-4

Standards-aligned

Created by

Kevon Kirton

Used 6+ times

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When trimming and reaming the cut ends of PVC conduit with a knife, electricians should wear __________.

goggles

an apron

leather or Kevlar gloves

no need for PPE

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When threading conduit you should wear safety glasses and proper foot and hand protection.

True

False

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Use a __________ fish tape when pulling or pushing wires in a conduit that is connected to an energized loadcenter.

nonconductive

conductive

round

metal

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To find the maximum number of conductors of the same size and insulation type permitted in various types and sizes of conduit, you would look in __________ of the NEC®.

Informative Annex D

Informative Annex C

Chapter 8

Chapter 9

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The NEC® defines __________ as an unthreaded thin-wall raceway of circular cross-section designed for the physical protection and routing of conductors and cables.

PVC

EMT

IMC

FMC

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Rigid metal conduit must be secured within __________ of outlet boxes, junction boxes, cabinets, and conduit bodies (general rule)

24 inches

12 inches

36 inches

6 inches

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The NEC® requires that a(n) __________ be used for the protection of conductors sized 4 AWG and larger installed in conduit.

antioxidant

insulated bushing

coupling

all of the above

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?