Earthing and Bonding-OSG

Earthing and Bonding-OSG

1st - 5th Grade

5 Qs

quiz-placeholder

Similar activities

G10 4Q - Ohm's Law

G10 4Q - Ohm's Law

2nd - 10th Grade

10 Qs

WWE

WWE

5th - 12th Grade

10 Qs

Inspection and testing

Inspection and testing

1st - 5th Grade

9 Qs

Acara larian

Acara larian

3rd - 6th Grade

10 Qs

Track Engineering - Ballast & Drainage

Track Engineering - Ballast & Drainage

KG - Professional Development

10 Qs

Electrical Test

Electrical Test

1st - 2nd Grade

5 Qs

Earth fault loop impedance

Earth fault loop impedance

1st - 5th Grade

10 Qs

Bosch 8

Bosch 8

1st - 4th Grade

10 Qs

Earthing and Bonding-OSG

Earthing and Bonding-OSG

Assessment

Quiz

Other

1st - 5th Grade

Hard

Created by

Adam Kerrigan

Used 8+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

5 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 5 pts

Which 1 of the following is an example of an extraneous-conductive part?

Metallic water installation pipes

Steel conduit

Metallic socket

Steel trunking

Answer explanation

The other three are examples of EXPOSED-conductive parts. Conductive parts of equipment/installation that are NOT normally but can be if basic insulation fails.

2.

MULTIPLE CHOICE QUESTION

1 min • 5 pts

What size earthing conductor would a 25mm mains distribution cable require for a TN-S supply?

6mm

10mm

25mm

16mm

Answer explanation

Section 4.4 Earthing conductor and main protective bonding conductor CSA-Table 4.4 (i)

3.

MULTIPLE SELECT QUESTION

1 min • 5 pts

Which of the following are types of earth electrode?

Earth rods or pipes

Earth tapes

Steel pipes

Aluminium rods

Answer explanation

Media Image

Section 4.10- List of earth electrodes. These are used for installations that require a TT earthing arrangement. The common type is the earth rod shown in the image.

4.

MULTIPLE CHOICE QUESTION

1 min • 5 pts

What is the recommended maximum earth fault loop impedance for a TT earthing arrangement?

100 Ohms

150 Ohms

200 Ohms

30 Ohms

Answer explanation

Media Image

Although it is recommended that a TT earthing arrangement does not exceed 200 ohms the value of 21 Ohms is the usual stated reading. Anything over 200 Ohms can become unstable due to environmental changes such as summer and winter.

5.

MULTIPLE CHOICE QUESTION

1 min • 5 pts

There is a yellow plastic incoming gas pipe in a domestic property. Is main protective bonding a requirement or a recommendation?

Recommendation

Requirement

Answer explanation

Media Image

Main protective bonding is NOT REQUIRED on plastic incoming services but IS RECOMMENDED. Section 4.5, page 57.