Quiz: Workshop 02

Quiz: Workshop 02

1st - 3rd Grade

10 Qs

quiz-placeholder

Similar activities

Our Universe

Our Universe

3rd Grade

10 Qs

Electric circuits

Electric circuits

1st Grade

8 Qs

Seismic Waves and Their Effects

Seismic Waves and Their Effects

3rd - 5th Grade

12 Qs

Solar System Vocabulary

Solar System Vocabulary

3rd Grade

12 Qs

Solar System

Solar System

3rd - 5th Grade

10 Qs

Faults

Faults

3rd Grade

10 Qs

Symmetrical fault analysis through bus impedance matrix

Symmetrical fault analysis through bus impedance matrix

1st Grade

10 Qs

SCIENCE

SCIENCE

3rd Grade

6 Qs

Quiz: Workshop 02

Quiz: Workshop 02

Assessment

Quiz

Science, Physics

1st - 3rd Grade

Medium

Created by

Amaya Silva

Used 1+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

Blackout is;

A fault

Total failure of the power system

Solar eclipse

Power cut period

2.

MULTIPLE CHOICE QUESTION

45 sec • 5 pts

System frequency is maintained at 50 Hz by;

Generators by changing their excitation

Consumers by switching off some of their loads

System operator making sure that generation is equal to demand all the time

None of the above

3.

MULTIPLE CHOICE QUESTION

45 sec • 5 pts

What happened on 26th Feb 2016 in Sri Lankan power system?

Disconnection of two critical 132 kV lines

Disconnection of two critical 220kV lines

It was a rainy day but power system was working as usual

There was a blackout created by supply-demand unbalance

4.

MULTIPLE CHOICE QUESTION

45 sec • 5 pts

Out of Step relay measures;

Fault current

Fault voltage

Impedance to the fault

None of the above

5.

MULTIPLE CHOICE QUESTION

45 sec • 5 pts

On the R-X plane, the operating point is closer to the origin;

When there is a fault

All the time

Under normal operating condition

During a blackout

6.

MULTIPLE CHOICE QUESTION

45 sec • 5 pts

To determine the appropriate setting for an out-of-step relay;

Need to wait till a few blackouts

Transient stability studies should be carried out

A comprehensive fault study should be carried out

Collect PMU data from many substations

7.

MULTIPLE CHOICE QUESTION

45 sec • 5 pts

Out-of-step event is classified as;

A wide-area event

A local event

A faulty event

None of the above

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?