[4] Quality Assurance (QA) for CT Scan

[4] Quality Assurance (QA) for CT Scan

University - Professional Development

15 Qs

quiz-placeholder

Similar activities

Quiz Tea Reward March & April 2021

Quiz Tea Reward March & April 2021

Professional Development

20 Qs

CT scanner

CT scanner

University

13 Qs

Musywil Fismed Jatim 2023

Musywil Fismed Jatim 2023

University

10 Qs

Medical Imaging

Medical Imaging

11th Grade - University

14 Qs

Chest Imaging

Chest Imaging

University

15 Qs

Evaluasi 1 - Kuliah Fisika Medis

Evaluasi 1 - Kuliah Fisika Medis

University

15 Qs

QuizZEM Series 1

QuizZEM Series 1

University

10 Qs

Evaluasi 2 - Kuliah Fisika Medis

Evaluasi 2 - Kuliah Fisika Medis

University

15 Qs

[4] Quality Assurance (QA) for CT Scan

[4] Quality Assurance (QA) for CT Scan

Assessment

Quiz

Professional Development, Physics, Science

University - Professional Development

Medium

Created by

Mohd Izuan

Used 5+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Which one is NOT the objective of performing quality assurance (QA) in CT Scan system?

Produce good image quality

Prevent unnecessary radiation dose to patient

Check for image artifact or machine mulfunction

To regulate the timetable for CT technologist

2.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Media Image

The American College of Radiology (ACR) CT accreditation QA phantom has _____ modules

4

5

6

7

3.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Which of the following cross section of ACR CT phantom used to check for "low contrast resolution"?

Media Image
Media Image
Media Image
Media Image

4.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Which of the following cross section of ACR CT phantom used to check for "CT number uniformity, noise & distance accuracy"?

Media Image
Media Image
Media Image
Media Image

5.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

The laser light accuracy in a CT scan machine must be within ______

1 mm

2 mm

3 mm

5 mm

6.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

A radiographer performed a slice thickness (ST) accuracy check for ST = 10 mm. The tolerance accepted value is ___________

0.5 mm

1 mm

1.5 mm

2 mm

7.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Low contrast resolution & high contrast resolution in CT scan system must be check _______

weekly

monthly

semi-annually (every 6 months)

annually (every 1 year)

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?