IBTE Weekly Test 2

IBTE Weekly Test 2

Assessment

Quiz

Created by

fiona phan

Professional Development

Professional Development

2 plays

Medium

Student preview

quiz-placeholder

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

High pressure promotes better absorption of light hydrocarbon in the absorber. Which is correct for the absorption tower?

Gas absorb C3 and C4 components of naphtha in absorption tower

Naphtha absorb C3 and C4 components of gas in absorption tower

Naphtha absorb C3, C4 and C5 components of the gas in absorption tower

Gas absorb C3, C4, C5 components of naphtha in absorption tower

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Stabilizer is a rectifying tower. Which one is correct for the stabilizer?

Absorption tower bottom oil is separated in the stabilizer, stabilized naphtha with qualified vapor pressure is obtained at the tower OVHD and LPG components (C3, C4) are obtained from the tower bottom

Absorption tower bottom oil is separated in the stabilizer, LPG components (C3, C4) are obtained at the tower OVHD and stabilized naphtha with qualified vapor pressure is obtained from the tower bottom

Desorption tower bottom oil is separated in the stabilizer, stabilized naphtha with qualified vapor pressure is obtained at the tower OVHD and LPG components (C3, C4) are obtained from the tower bottom

Desorption tower bottom oil is separated in the stabilizer, LPG components (C3, C4) are obtained at the tower OVHD and stabilized naphtha with qualified vapor pressure is obtained from the tower bottom

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the main operating absorber OVHD pressure and OVHD temperature?

0.87MPa and 24ᵒC

 0.87MPa and 55ᵒC

1.0MPa and 24ᵒC

1.0MPa and 55ᵒC

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the main operating desorber OVHD pressure and OVHD temperature?

0.87MPa and 24ᵒC

1.1MPa and 55ᵒC

1.1MPa and 24ᵒC

1.0MPa and 55ᵒC

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the main operating Stabilizer OVHD pressure and OVHD temperature?

1.1MPa and 69ᵒC

1.1MPa and 55ᵒC

1.0MPa and 24ᵒC

1.0MPa and 55ᵒC

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the heat source of desorber bottom reboiler 1012-E-630R?

Atm 2# PA

Atm 2nd Side-draw

1.0MPa steam

0.5MPa steam

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the heat source of stabilizer bottom reboiler 1012-E-640R/S?

Atmospheric distillation tower 2# PA

Atmospheric distillation tower 2nd Side-draw

1.0MPa steam

. 0.5MPa steam

Explore all questions with a free account

or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?