2391-51

2391-51

1st - 12th Grade

40 Qs

quiz-placeholder

Similar activities

chapitre 12

chapitre 12

KG - 7th Grade

39 Qs

Unit 5: Judicial Branch Review

Unit 5: Judicial Branch Review

8th - 12th Grade

44 Qs

Electricity and Circuits

Electricity and Circuits

6th Grade

35 Qs

random quiz

random quiz

5th - 10th Grade

35 Qs

Auto 1 Semester Final 2024

Auto 1 Semester Final 2024

9th - 12th Grade

40 Qs

2391-50 Inspection and Testing

2391-50 Inspection and Testing

1st - 12th Grade

40 Qs

Fault Diagnosis & Rectification - Quiz 3

Fault Diagnosis & Rectification - Quiz 3

12th Grade

45 Qs

2391-51

2391-51

Assessment

Quiz

Other

1st - 12th Grade

Hard

Created by

Chris Falet

Used 13+ times

FREE Resource

40 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

What would be the correct procedure to confirm that the existing electrical installation in a dwelling is suitable for the additional wiring of an extension?

a) A visual inspection of the wiring and condition of the accessories.

b) A full review of the original electrical installation certificate.

c) Certification of the additional wiring on completion of the extension.

d) A periodic inspection and test of the existing installation.

2.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

What is the purpose of a periodic inspection and test relating to the safety of the building?

a) There is no risk of electric shock and burns.

b) There is no risk of fire caused by the electrical installation.

c) That the electrical installation is not damaged.

d) That there are no defects or non-compliances present.

3.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Media Image

What is the minimum level of IP protection for the opening shown as Item A in Figure 1?

a) IP4X

b) IPX4

c) IP2X

d) IPX2

4.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

What is the minimum level of IP protection for the accessible top surface of a consumer unit?

a) IP4X

b) IPX4

c) IP2X

d) IPX2

5.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Which publication gives detailed information for carrying out testing of electrical installations?

a) HSE GS 38

b) IET Guidance Note 3

c) IET Guidance note 1

d) HS(G)141

6.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

What would be agreed with the client and recorded as a limitation for a periodic inspection and test?

a) No insulation resistance testing between live conductors to be carried out.

b) The installation can be isolated and a full range of tests to be carried out.

c) The finalised report is to be provided to the client electronically.

d) Only calibrated test instruments are to be used.

7.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Which statutory document includes the requirements for working on live conductors?

a) The Electricity Safety Quality and Continuity Regulations.

b) The Construction (Design and Management) Regulations.

c) The Health and Safety at Work Act.

d) The Electricity at Work Regulations.

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?