Earth Continuity Testing & Fault Finding

Earth Continuity Testing & Fault Finding

Professional Development

10 Qs

quiz-placeholder

Similar activities

Digital Quiz

Digital Quiz

Professional Development

10 Qs

NBA Trivia

NBA Trivia

KG - Professional Development

11 Qs

18th edition part 2 mock 1

18th edition part 2 mock 1

Professional Development

10 Qs

Mario Kart

Mario Kart

Professional Development

10 Qs

1A Electrical

1A Electrical

Professional Development

14 Qs

MPRE QUIZ

MPRE QUIZ

Professional Development

10 Qs

Operational Risk Awareness

Operational Risk Awareness

Professional Development

10 Qs

Manteniment xarxa contactes i col·laboradors

Manteniment xarxa contactes i col·laboradors

Professional Development

14 Qs

Earth Continuity Testing & Fault Finding

Earth Continuity Testing & Fault Finding

Assessment

Quiz

Other

Professional Development

Medium

Created by

Andrew Selby

Used 40+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following tests would be carried out 'live':

insulation resistance

earth continuity

prospective fault current

ring circuit continuity

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following requirements from GS 38 applies to test equipment which requires more than one test lead?

The leads must be at least 1m in length

The leads must have a c.s.a. of at least 1.5 mm2

The leads must be colour coded for identification

The leads must be permanently attached to the instrument

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The test probes on leads used with electrical test equipment must be insulated and with exposed metal tips not exceeding?

2mm

3mm

4mm

Only spring loaded retractable screened probes to be used

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the wire size for Main earthing conductor ?

10mm2

6mm2

16mm2

2.5mm2

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A continuity test as part of fault diagnosis would be carried out with which instrument:

Earth-fault loop impedance tester

High resistance ohmmeter

Low resistance ohmmeter

RCD Tester

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On inspection of terminations at a motor, you observe conductor insulation has melted and discolouring of the terminal metal the most likely cause would be:

Overcurrent

Loose connection

Open circuit

Short Circuit

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An RCD would protect against the following fault:

Open circuit

Overcurrent

Short circuit between live conductors