EI8551-AI-Unit 1-1.8-Flame Emission Photometry

EI8551-AI-Unit 1-1.8-Flame Emission Photometry

1st - 3rd Grade

10 Qs

quiz-placeholder

Similar activities

Spaghetti

Spaghetti

KG - 12th Grade

10 Qs

OFC C1 Batch MCQ

OFC C1 Batch MCQ

1st - 5th Grade

10 Qs

Cimate Change and I

Cimate Change and I

2nd Grade

7 Qs

Quiz No.3

Quiz No.3

1st - 3rd Grade

10 Qs

Fun Quiz-3

Fun Quiz-3

1st - 10th Grade

10 Qs

Technique d'accueil téléphonique

Technique d'accueil téléphonique

1st Grade

15 Qs

EI8551-AI-Unit 1-1.8-Flame Emission Photometry

EI8551-AI-Unit 1-1.8-Flame Emission Photometry

Assessment

Quiz

Education

1st - 3rd Grade

Hard

Created by

MohanRaj K

Used 12+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The function of pressure regulators in the emission system of a flame photometer is to have a steady flame which is free from flickers.

True

False

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In the Total consumption burner, only samples of particular droplet size will enter the burner.

True

False

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is the principle of Flame emission photometers?

a) Radiation is absorbed by non-excited atoms in vapour state and are excited to higher states

b) Medium absorbs radiation and transmitted radiation is measured

c) Colour and wavelength of the flame is measured

d) Only wavelength of the flame is measured

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In Flame emission photometers, the measurement of _____________ is used for qualitative analysis

a) Colour

b) Intensity

c) Velocity

d) Frequency

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In Flame emission photometers, the measurement of _____________ is used for quantitative analysis

a) Colour

b) Intensity

c) Velocity

d) Frequency

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is not an advantage of Laminar flow burner used in Flame photometry?

a) Noiseless

b) Stable flame for analysis

c) Efficient atomization of sample

d) Sample containing two or more solvents can be burned efficiently

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Laminar flow burner used in Flame photometers is also known as ____________

a) Turbulent burner

b) Premix burner

c) Total consumption burner

d) Nozzle mix burner

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?