#5 EPA 608 Type III

#5 EPA 608 Type III

11th Grade - Professional Development

25 Qs

quiz-placeholder

Similar activities

#6 EPA 608 Type III

#6 EPA 608 Type III

11th Grade - Professional Development

25 Qs

#3 EPA 608 Type I

#3 EPA 608 Type I

11th Grade - Professional Development

25 Qs

EPA Section 608 Exam: Type III

EPA Section 608 Exam: Type III

9th - 12th Grade

20 Qs

gw 50 spring 2025

gw 50 spring 2025

University

21 Qs

HAC-101 Chap 58 Principles of HVAC Test B

HAC-101 Chap 58 Principles of HVAC Test B

University

20 Qs

EPA 608 Prep: Type II

EPA 608 Prep: Type II

9th - 12th Grade

20 Qs

Type 3 Quiz

Type 3 Quiz

Professional Development

20 Qs

Pre-Test

Pre-Test

1st Grade - University

20 Qs

#5 EPA 608 Type III

#5 EPA 608 Type III

Assessment

Quiz

Other

11th Grade - Professional Development

Easy

Created by

Mike Conway

Used 269+ times

FREE Resource

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A chiller with a charge of 200 pounds has passed the initial verification leak test. When must a follow ­up verification test be conducted?

The same day.

The next day.

Within 10 days.

Within 30 days.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What evacuation level must technicians recover refrigerant to before disposing a low-pressure appliance?

0 psig

15 inches of Hg vacuum

25 inches of Hg vacuum

25 mm of Hg absolute

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A rupture disc on a recovery vessel for low-pressure refrigerants relieves at;

5 psig.

10 psig.

15 psig.

20 psig.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On low-pressure chillers, moisture most frequently enters the refrigerant system through;

air leaks in the rupture disc assembly.

tube leaks in the evaporator.

leaks from areas with gaskets or fittings.

leaks from the charging service valve.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How long must owners and operators of low-pressure chillers using HCFC refrigerant keep records of leak inspections, initial verification, and follow-up verification tests?

2 years

3 years

5 years

Life of the appliance

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Starting in 2019, what is the leak rate threshold for comfort cooling appliances with a full charge of 50 or more pounds?

5%

10%

20%

30%

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where is the lowest access point on a low-pressure centrifugal air-conditioning appliance?

Evaporator charging valve.

Condenser service valve.

Compressor cooler jacket.

Purge unit exhaust port.