Unsafe Situations

Unsafe Situations

1st - 3rd Grade

10 Qs

quiz-placeholder

Similar activities

uso de la c , s, z

uso de la c , s, z

KG - University

8 Qs

Fortnite S.7

Fortnite S.7

2nd Grade - Professional Development

6 Qs

Imam As-Syafie r.h

Imam As-Syafie r.h

1st Grade - University

11 Qs

Marketing 101

Marketing 101

1st Grade

8 Qs

Contractions

Contractions

3rd Grade

13 Qs

PAI & BUDI PEKERTI KLS 3 SEMESTER 1 HAL 026 PH 3

PAI & BUDI PEKERTI KLS 3 SEMESTER 1 HAL 026 PH 3

3rd Grade

10 Qs

 Construction health and safety brickwork

Construction health and safety brickwork

1st - 3rd Grade

10 Qs

TNGH Periode Juli Agustus 2025

TNGH Periode Juli Agustus 2025

1st Grade

10 Qs

Unsafe Situations

Unsafe Situations

Assessment

Quiz

Other

1st - 3rd Grade

Medium

Created by

Rober Kerr

Used 15+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When servicing a gas appliance you find spillage issues. This would be classed as

AR

ID

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When servicing an open-flued appliance, you find that the appliance is operating safely but that there is insufficient ventilation being provided. this is classed a

ID

AR

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

you find that undersized pipework proves to be affecting the safe operation of an appliance. This would be classed as

ID

AR

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

pipework proved gas tight but showing signs of damage from corrosion should be classed as

AR

ID

no need for classification

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

After proving an installation sound, there continues to be a smell of gas and turning off the ECV does not solve the problem. You must

no action required on your part

inform the gas supplier immediately

explain to the customer that they have nothing to worry about

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

There is a serious flue defect, you must

turn off the appliance and put a do not use label on it

disconnect the appliance from the supply and put a do not use label on it

advise the customer not to use it

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

when inspecting room-sealed concealed flue system, you find there is a lack of appropriate inspection hatches in the ceiling void. This would be classed as

ID

AR

no need for classification if flue functioning correctly

advise customer only of need for inspection hatches

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?